4. MODE SETTING AND AUXILIARY FUNCTION
The auxiliary function is set with the built-in switch of the unit. In order to change the
setting, remove the cover by detaching 4 screws on the side of the CCU.
Switch layout (cover removed)
-IMPORTANT
When operating the internal switch or using the soldering iron, the built-in circuit of
the unit is exposed, which may hazardous condition of breaking static electricity.
In order to prevent the static electricity breaking, make sure to duly observe the fol
lowing items upon the operation.
© Do not touch any parts and boards other than the switch required to be operated.
@ Do not wear the cloth which is likely to cause static electricity, such as nylon, rubber or
the like. Make sure to put on cotton gloves when carrying out the operation.
® Put on the earth band with the arm for earthing. If the earth band is not available,
touch GND of BNC connector pin before starting the operation.
® Cover the working table with the conductive sheet for earthing.
® Earth GND of the BNC connector pin of the set.