Mode
External
input
signal
S309
trigger
mode
setting
S308
Shutter speed
Remarks
1
2 I 3
4
5
6
7 I 8
Field/
Frame
accumulalion
Output
field
External
SYNC
(onlyVD)
Non
interlaced
H.V
Reset
Shutter at
intervals of 1H
s
w
ffl
DC
Trigger input, SYNC non-reset,
non-interlaced, HD: External sync.
Trigger,
HD
7
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
Set with rotary switch S307
Reset/restart by trigger inputting, but SYNC
is not reset by trigger inputting.
Trigger input, SYNC non-reset,
non-interlaced, VD: External sync.
Trigger,
VD
7
OFF
OFF
OFF
ON
ON
OFF
OFF
OFF
Set with rotary switch S307
Reset/restart by trigger inputting, but SYNC
is not reset by trigger inputting.
Trigger input, SYNC non-reset,
non-interlaced, HD/VD: External sync.
Trigger,
HD, VD
7
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
Set with rotary switch S307
Reset/restart by trigger inputting, but SYNC
is not reset by trigger inputting.
Trigger input, SYNC non-reset,
non-interlaced, C-SYNC/VBS/VS: External sync.
Trigger,
C-SYNC/VBS/VS
7
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
Set with rotary switch S307
Reset/restart by trigger inputting, but SYNC
is not reset by trigger inputting.
O)
O)
«
3
Q.
d>C
O
SYNC reset
Trigger
4
OFF
Can be set
OFF
OFF
ON
Can be set
Set with rotary switch S307
Set at intervals of 1H with S302
The mode where video is output
immediately after trigger inputting.
SYNC reset, HD input
Trigger,
HD
4
OFF
Can be set
OFF
OFF
OFF
Can be set
Set with rotary switch S307
Set at intervals of 1H with S302
The mode where video is output
immediately after trigger inputting.
SYNC non-reset,
HDA/D: Internal sync.
Trigger
6
OFF
Can be set
OFF
OFF
OFF
Can be set
Set with rotary switch S307
Set at intervals of 1H with S302
SYNC is not reset by trigger inputting.
SYNC non-reset,
HD: External sync.
Trigger,
HD
6
OFF
OFF
OFF
OFF
OFF
OFF
Can be set
Set with rotary switch S307
Set at intervals of 1H with S302
SYNC is not reset by trigger inputting.
SYNC non-reset,
VD: External sync.
Trigger,
VD
6
OFF
OFF
OFF
ON
OFF
OFF
Can be set
Set with rotary switch S307
Set at intervals of 1H with S302
SYNC is not reset by trigger inputting.
SYNC non-reset,
HD/VD: External sync.
Trigger,
HD, VD
6
OFF
OFF
OFF
OFF
OFF
OFF
Can be set
Set with rotary switch S307
Set at intervals of 1H with S302
SYNC is not reset by trigger inputting.
SYNC non-reset,
C-SYNCA/BS/VS: External sync.
Trigger,
C-SYNC/VBS/VS
6
OFF
OFF
OFF
OFF
OFF
OFF
Can be set
Set with rotary switch S307
Set at intervals of 1H with S302
SYNC is not reset by trigger inputting.
S308 No.1 Field/Frame accumulation
ON Frame accumulation
OFF Field accumulation
S308 No.2, No.3 Output field designation
S308
Output field
No.2
No.3
ON
OFF
ODD field
ON
ON
EVEN field
OFF
ON
Designation OFF
OFF
OFF
Designation OFF
N)