53u_6_7.pdf, Programming user settings – Braeburn 5300 2H-2C User Manual User Manual
Page 4
7
2.4.6 Setting the Recirculating Fan Cycle (see also section 3.9)
13. Press the RETURN button, the display will show “XXX SET OC”, where “XXX” is the Recirculating Fan off cycle.
14. Press the or button to change the Recirculating Fan off cycle to the desired value of 120, 60, 40
or 24 minutes.
15. Press the RETURN button again to return to the normal mode, or wait 30 seconds for the thermostat to
return automatically.
2.5 Setting Your Energy Saving Programs – Tips Before Starting
NOTE:
If the thermostat is in the non-programmable mode you
cannot set an Energy Savings Program. The System mode, Time,
Day, Temperature and Fan mode will be displayed when the
thermostat is in the non-programmable mode.
• It is important for you to set the current time of day (note the
AM/PM indicator in the display), and the current day of week
correctly to avoid problems with program execution. This must be done prior to entering any program settings.
• The heating and cooling programs have both separate setpoint times and setpoint temperatures, unless auto
changeover is enabled. If auto changeover is enabled during Installer Setup, (see section 4.2 of the Installer
Guide) the heating and cooling programs have common heating and cooling setpoint times with separate
setpoint temperatures.
• This thermostat is preprogrammed with Residential 4 events per day times and temperatures recommended
by the Environmental Protection Agency and the U.S. Department of Energy in their ENERGY STAR
®
program.
These settings provide efficient energy savings during normal heating and cooling modes of operation. If you
wish to use the settings in the table, no further programming is necessary. Review these time and temperature
settings prior to establishing your personal program settings to maximize your savings, and minimize
programming requirements.
2
PROGRAMMING
USER SETTINGS
cont.
6
All Days 2 Event All Days
MORN
DAY
EVE
NIGHT
Time: 6:00 pm
Heat: 70˚ F (21˚ C)
Cool: 75˚ F (24˚ C)
Time: 8:00 am
Heat: 62˚ F (17˚ C)
Cool: 83˚ F (28˚ C)
Time: 6:00 am
Heat: 70˚ F (21˚ C)
Cool: 75˚ F (24˚ C)
Time: 10:00 pm
Heat: 62˚ F (17˚ C)
Cool: 78˚ F (26˚ C)
Time: 8:00 am
Heat: 70˚ F (21˚ C)
Cool: 75˚ F (24˚ C)
Occupied
4 Event
SYSTEM
FAN
MO
COOL
AUTO
PM
Unoccupied
Time: 6:00 pm
Heat: 62˚ F (17˚ C)
Cool: 83˚ F (28˚ C)
2.5 Setting Your Energy Saving Programs
cont.
2
PROGRAMMING
USER SETTINGS
cont.
NOTE:
If the Commercial (BUS) programming mode was selected during the Installer Setup (Installer Guide),
the default program is the 2 events per day shown in the chart above.