beautypg.com

53u_26_bck.pdf, Troubleshooting, Store this booklet for future reference – Braeburn 5300 2H-2C User Manual User Manual

Page 14

background image

26

4

TROUBLESHOOTING

SYMPTOM

POTENTIAL SOLUTION

cont.

LO is shown in the
thermostat display
where the room
temperature is
normally displayed.

The temperature sensed by the thermostat is lower than the 40˚ F (5˚ C) lower limit of
the thermostats display range. The display will return to normal after the sensed
temperature rises within the 40˚ to 99˚ F (5˚ to 37˚ C) display range. If the temperature
in the controlled space seems to be normal, wait for the thermostat to acclimate to the
correct room temperature. If the room seems to be colder than usual, turn on the heating
system to raise the temperature as needed for comfort within the room.
This condition could occur from the system being turned off during a cold weather period
or upon installation when the thermostat has been stored for a long period of time in a
cold vehicle or location prior to being installed. The thermostat should be allowed to
warm up prior to installation to allow proper heating control once installed.

Thermostat will not
allow me to change
the setpoint.

Fan continues to run
all the time whether
the system is on
or off.

Check that the fan is in the

AUTO mode. This will allow the fan to run only when the

heating or cooling system is turned on and running.
Check thermostat wiring to make sure that the fan control wiring is connected to the
correct terminals on the wiring terminal block. See section 6 of the Installer Guide.

Unit will not enter
program mode.

Non-Programmable mode selected during Installer Setup. See section 4.2 of the
Installer Guide.

Store this

booklet for

future reference

© 2006 Braeburn Systems LLC • Patents Pending • All Rights Reserved. Pub. No. 5300-110-002

Braeburn Systems LLC warrants each new Braeburn thermostat against any defects that are

due to faulty material or workmanship for a period of five years after the original date of

purchase by a professional service technician. This warranty and our liability does not apply to

batteries, nor does it include damage to merchandise or the thermostat resulting from

accident, alteration, neglect, misuse, improper installation or any other failure to follow

Braeburn installation and operating instructions.

Braeburn Systems LLC agrees to repair or replace at its option any Braeburn thermostat

under warranty provided it is returned postage prepaid to our warranty facility in a padded

carton within the warranty period, with proof of the original date of purchase and a brief

description of the malfunction. This limited warranty does not include the cost of removal or

re-installation.

This warranty gives you specific legal rights and you may also have other rights that vary from

state to state or province to province. Answers to any questions regarding our limited warranty

may be obtained by writing our corporate offices.

Braeburn Systems LLC
2215 Cornell Avenue • Montgomery, IL 60538
Technical Assistance: www.braeburnonline.com
Call us toll-free: 866-268-5599 (U.S. Only)
630-844-1968 (Outside the U.S.)

WARRANTY FACILITY: Braeburn Systems LLC

Attn: Warranty Department

2215 Cornell Avenue

Montgomery, IL 60538

The Keypad is locked. To lock or unlock the keypad, press and hold both the and
buttons at the same time for 5 seconds. The LOCK segment in the display will flash
as the program and temperature segments are cleared (see section 3.7). The time
segments will turn to zeros. Enter the 3 digit code programmed in section 2.4.5 of
this manual. After setting the last digit, press the

RETURN key for 1 second. The

display will return to the normal mode. If an incorrect code is entered, the display
will flash “

no”.