Code configuration command for tuning (WC/RC)
Modifications
Addition
Operation configuration command (WP/RP)
Addition
Function
Command
number
Setting value
Explanation
Default
CODE39
settings
0600
03 to 50
Maximum read length
50
0601
03 to 50
Minimum read length
3
0602
4 to 11
Quiet zone scale factor
7
0604
0,1
Inspect check-digit
* For settings to read Trioptic
CODE39, this setting does not
function.
0
0605
0,1
Send check-digit
* For settings to read Trioptic
CODE39, this setting does not
function.
1
0607
0,1
FullASCII conversion
* For settings to read Trioptic
CODE39, this setting does not
function.
0
Function
Command
number
Setting value
Explanation
Default
PDF417
settings
0300
0001 to 2710 Maximum read length
2710
0301
0001 to 2710 Minimum read length
1
0303
1 to 3
PDF417 read code type settings
1: PDF417 only
2: MicroPDF only
3: PDF417 and MicroPDF
3
CODE39
settings
0606
0,1
Read Trioptic CODE39
0: Disable
1: Enable
1
2 of 5
(Industrial
2of5) settings
0800
01 to 50
Maximum read length
50
0801
01 to 50
Minimum read length
4
0802
4 to 11
Quiet zone scale factor
7
COOP 2of5
settings
1200
02 to 50
Maximum read length
50
1201
02 to 50
Minimum read length
4
1202
4 to 11
Quiet zone scale factor
7
CODE93
settings
1300
01 to 50
Maximum read length
50
1301
01 to 50
Minimum read length
1
1302
4 to 11
Quiet zone scale factor
7
Function
Command
number
Setting value
Explanation
Default
Bank shift
shortening
operation
214
0,1
If it has been determined that the
code is not present in the scanned
image, set whether to shift to the next
scanning operation without waiting for
the decode timeout period expiration.
0: Disable
1: Enable
1
Implementation
of Japanese
Pharmaceutical
Code quality
verification
234
0 to 1F
0: Not selected
1: GS1-128
2: GS1 DataBar Limited
4: GS1 DataBar Stacked
8: CC-A(GS1-DataBar Limited)
10: CC-A(GS1-DataBar
Stacked)
The setting value for this item is
treated as HEX.
The setting is specified with HEX
using sum of each item.
0
Japanese
Pharmaceutical
Code quality
verification
threshold
235
0 to 4
0: Disable
1: D
2: C
3: B
4: A
0
Verification
result addition
setting for
Japanese
Pharmaceutical
Code
344
0,1
0: Do not append
1: Append
0
Composite
Code delimiter
605
hhhhhh...
Specify a maximum of 5 characters
(HEX 10 bytes) with HEX (0x00 to
0x7F).
FF : Not selected
FF
6 Other Modifications
Modifications on Ethernet cable
Along with the changed Ethernet cable (OP-87359/87360/87361), the outline
dimensional drawing has been changed as shown in the figure below.
Script function
Regarding the additional functions, the script function used for the Edit data
function/Edit image file name function has been added.
For details, refer to
"SR-D100/750 Series Script Reference Rev.4.0".
7 Precautions
GS1 DataBar Limited and CC-A/B(GS1 DataBar Limited)
GS1 DataBar Limited (including GS1 DataBar Limited as a part of CC-A/B) is
characterized by being closely similar to some portion of other barcodes in terms of
the bar structure.
Accordingly, the standard regarding GS1 DataBar Limited was amended in 2011.
The amended standard requires that a trailing space five times the width of the
narrow bar is maintained to the right of GS1 DataBar Limited.
For materials with a blackish surface, if the space portion is printed with a laser
marker, the marker may not comply with the new standard. In this case, the SR-
750 Series cannot be tuned with the factory setting.
If tuning is not possible with these printed codes, set the Limited right space scaling
factor as 0 and retry tuning.
A space 5 times the area
shown here must be
secured.