Appended data output data format, Appended data output order, 4 modifications to autoid network navigator – KEYENCE SR-750 Series User Manual
Page 5: 4 modifications to autoid net- work navigator, Addition of tuning target codes, Addition of code quality verification items, Addition of data edit items, Addition of other tabs
5
SR-750_AFM_E
Appended data Output data format
Appended data Output order
Unused error correction
UEC
(Unused Error Correction)
Description
Evaluates the ratio of error correction unused
at the time of decoding.
-
Calculation
formula
UEC = 1.0 – ((e + 2t) / ( d – p))
e : Number of codewords that cannot be
read
t
: Number of error codewords
d : Number of error corrected codewords
p : Number of error detected codewords
Criterion
A : UEC
≥ 0.62
B : UEC
≥ 0.50
C : UEC
≥ 0.37
D : UEC
≥ 0.25
F : UEC < 0.25
Setting
Data format example
Grade
Format
Detailed item
addition
Evaluation
value addition
Japanese
Pharmaceutical
Code
quality
verification
(Composite
Symbol)
Alphabet
Ч
Ч
Read data:C:A:C
×
○
Read data:C(-):A(-):C(-)
○
×
Read data:C:A/A/A/A/A/A/A/A/
A/A:C/C/C/A/A/A/A/C/C/A/A/A/
A
○
○
Read data:B(-):A(-)/A(1.000)/
A(1.000)/A(0.938)/A(0.059)/
A(0.871)/A(0.930)/A(1.000)/
A(0.797)/A(0.031):B(-)/
B(0.711)/B(0.711)/A(0.945)/
A(0.055)/A(0.895)/A(0.945)/
B(0.711)/A(0.633)/A(0.012)/
A(0.914)/B(0.750)/A(0.750)
Number
Ч
Ч
Read data:2.8:4.0:2.8
×
○
Read data:2.8(-):4.0(-):2.8(-)
○
×
Read data:2.1:4.0/4.0/4.0/4.0/
4.0/4.0/4.0/4.0/4.0/4.0:2.1/3.0/
3.0/4.0/4.0/4.0/4.0/3.0/4.0/4.0/
4.0/4.0/4.0
○
○
Read data:3.4(-):4.0(-)/
4.0(1.000)/4.0(1.000)/
4.0(0.934)/4.0(0.063)/
4.0(0.867)/4.0(0.930)/
4.0(1.000)/4.0(0.805)/
4.0(0.031):3.4(-)/4.0(1.000)/
4.0(1.000)/4.0(0.941)/
4.0(0.055)/4.0(0.793)/
4.0(0.840)/4.0(1.000)/
4.0(0.832)/4.0(0.066)/
4.0(0.914)/4.0(0.750)/
4.0(0.750)
Name of standard
Evaluation item name (English)
Abbreviated
name
Japanese Pharmaceutical
Code quality verification
1D & 2D Overall Composite Symbol
ALL
1D
Overall
ALL
Decode
DEC
EdgeDetermination
EDGE
Symbol Contrast
SC
Minimum Reflectance
MINR
Minimum Edge Contrast
MINE
Modulation
MOD
Quiet Zone
QZ
Decodability
DCD
Defects
DEF
2D
Overall
ALL
Decode
DEC
EdgeDetermination
EDGE
Symbol Contrast
SC
Minimum Reflectance
MINR
Minimum Edge Contrast
MINE
Modulation
MOD
Quiet Zone
QZ
Decodability
DCD
Defects
DEF
Codeword Yield
CY
Codeword Print Quality
CPQ
Unused Error Correction
UEC
4 Modifications to AutoID Net-
work Navigator
Addition of tuning target codes
It is possible to set the newly added code types.
Addition of code quality verification items
It is possible to set the newly added Japanese Pharmaceutical Code quality
verification function.
Addition of data edit items
It is possible to set appended data for the newly added Japanese Pharmaceutical
Code quality verification.
Addition of other tabs