beautypg.com

Symbology for code quality verification, Description of verification items, 3 details of japanese pharmaceutical code quality – KEYENCE SR-750 Series User Manual

Page 3: Verification function, Coop2of5, Code39(trioptic code39)

background image

3

SR-750_AFM_E

„

COOP2of5

Quiet zone scale factor (4-11).......Set the quiet zone scale factor.

„

CODE39(Trioptic CODE39)

Trioptic CODE39......................Check this to allow reading of Trioptic CODE39.

3 Details of Japanese Pharmaceutical

Code Quality Verification Function

Symbology for code quality verification

• GS1-128
• GS1 DataBar Limited
• GS1 DataBar Stacked
• CC-A (GS1 DataBar Limited)
• CC-A (GS1 DataBar Stacked)

Settings of the Japanese Pharmaceutical Code quality
verification function

To use the Japanese Pharmaceutical Code quality verification function, you need
to enable the verification settings.
(1) Setting using the AutoID Network Navigator

Press the "Code quality verification" button on the "Operation" tab in the
Settings view, and then check "Japanese Pharmaceuticals". In addition, select
the code to be verified.

Name of verification function

Explanation

Japanese Pharmaceutical Code quality
verification

Function for evaluating the print quality of codes on
pharmaceuticals, recommended by the Safety
Division of Pharmaceutical and Food Safety Bureau
and the Economic Affairs Division of Health Policy
Bureau under the Ministry of Health, Labour and
Welfare.
It makes reference to ISO/IEC15415 and ISO/
IEC15416.

(2) Setting using the setup commands

Send commands that enable the Japanese Pharmaceutical Code quality
verification function.
For configuration commands, refer to

"5 Modified and Added Configuration

Commands" (Page 6).

Point

When the Code quality verification function is enabled, the decode
time becomes longer than when it is disabled.
Perform calibration after enabling the Code quality verification
function or set the decode timeout period required for reading.
Use the tact measurement test mode to confirm that there is no
problem with the reading time for operation.

„

Other settings, functions, and precautions regarding the
code quality verification

The following settings, functions, and precautions are similar to those of ISO/
IEC15415.
For details, refer to

"3-11 Code quality verification function in SR-750 Series

User's Manual".
• Append Code quality verification result data
• For the data format with data appended, refer to

"Other Modifications" (Page

7).

• Code quality verification function Evaluation standard
• Functions that can use evaluation results of the Code quality verification function
• Notes when using the Code quality verification function

Description of verification items

Japanese Pharmaceutical Code quality verification
(GS1 DataBar Limited, GS1 DataBar Stacked, GS1-128)

Decode success/failure

DEC (Decode)

Description

Evaluates whether decoding is possible or not.

-

Calculation
formula

-

Criterion

A : Success
F : Failure

Number of edges

EDGE (EdgeDetermination)

Description

Determines whether the read number of edges
is equal to the assumed number of edges.

-

Calculation
formula

-

Criterion

A : Match
F : Mismatch

Symbol contrast

SC (Symbol Contrast)

Description

Evaluates the difference between the
maximum brightness value (Rmax) and
minimum brightness value (Rmin) in the code
area.

-

Calculation
formula

SC = Rmax – Rmin

Criterion

A : SC

≥ 70 %

B : SC

≥ 55 %

C : SC

≥ 40 %

D : SC

≥ 20 %

F : SC < 20 %

Minimum Reflectance

MINR

(Minimum Reflectance)

Description

Minimum reflectance among scanned
waveforms

-

Calculation
formula

-

Criterion

A : Rmin

≤ 0.5 Rmax

F : Rmin > 0.5 Rmax