1 sj-m series operations, Setup overview, Sj-m series operations – KEYENCE SJ-M400 User Manual

Page 6

background image

6

3-1

SJ-M Series Operations

This section describes the setting and operation of the SJ-M Series.

Setup Overview

A brief overview of the setup procedure for the SJ-M Series is provided below.

1. Selecting an operation mode

Use the operation mode selector switch to change the operation mode.

Operation mode selection

1. Operation mode selection

Select an operation mode.Select the operation

mode using the operation mode selector switch.

Settings adjustment

2. Settings adjustment

Change the settings for the SJ-M400.

Ion balance adjustment

3. Ion balance adjustment

The zero point, the point for reference for the I.C.C.

function, can be adjusted.

(* The zero point should only be adjusted when

necessary.)

S

G

T

SPOT MODE

GUN MODE

TEST MODE

SPOT MODE

This mode is used to continuously perform static
elimination by installing the static elimination head within
a device.
The valve output of the terminal (2) turns ON/OFF while
the terminals (3) and (6) are shorted out.

"Timing Charts" (page 10)

Static elimination is turned ON/OFF in the cycle specified
in the "Valve control frequency setting".

GUN MODE

This mode is used to frequently turn ON/OFF static
elimination by installing the static elimination head within
an air gun.

TEST MODE

This is the output terminal test mode. Alarm signals such
as ion level alarm and condition alarm signals are output
and static elimination stops.

* Switching the operating mode will reboot the SJ-M Series.

3-1

SJ-M Series Operations

2. Changing settings

Setting adjustment overview

This section provides details regarding settings and a brief overview of the setup procedure used for
changing operation modes on the SJ-M Series.

Setting items

Run mode

Setup mode

[Setting items]

[Detailed settings]

Either lights up

Normal operation state.

Select setting items.

Select detailed settings.

Blink alternately

Blink alternately fast

Hold down

and

simultaneously
for at least 1
second.

Hold down
for at least
1 second.

Press
for a
short time.

Press
for a
short time.

Run mode

Setup mode

[Setting items]

[Detailed settings]

Ion level alarm
sensitivity setup

Sensitivity: High
Sensitivity: Medium
Sensitivity: Low
Sensitivity: None

Sensitivity: High
Sensitivity: Medium
Sensitivity: Low
Sensitivity: None

Condition alarm
sensitivity setup

I.C.C. ON
I.C.C. OFF

High:11.5Hz
Medium:5.8Hz
Low:3.8Hz

I.C.C. ON/OFF
setting

Valve control
frequency setting

Initialization of
settings

3-1

SJ-M Series Operations

Procedure for changing settings

The procedure for changing settings for the SJ-M Series is as follows.

1

Check that the unit is in Run mode.

2

Hold down

and

for at least one second to enter

setting item selection in Setup mode.

3

Press

or

to

select

the

item

to

be

set.

For details on items, see "Setting items" on page 7.

4

Press

to select detailed Setup mode settings for

adjustment.

Either lights up

[Run mode]

Either "BALANCE" or "ION" lights up.

Tip

[Setup mode]

Blink alternately

"BALANCE" and "ION" blink alternately.

Tip

[Setup mode]

Blink alternately fast

"BALANCE" and "ION" blink alternately fast.

Tip

3-1

SJ-M Series Operations

5

Press

or

to

select

the

item

to

be

set.

For details on items, see "Setting items" on page 7.

6

Press

to return to setting item selection in Setup mode.

To change other items, repeat the procedure from steps 4 to 6.

7

Hold down

for at least one second to return to Run mode.

Setting adjustment is now complete.

[Setup mode]