1 sj-m series operations, Setup overview, Sj-m series operations – KEYENCE SJ-M400 User Manual
Page 6
![background image](/manuals/658061/6/background.png)
6
3-1
SJ-M Series Operations
This section describes the setting and operation of the SJ-M Series.
Setup Overview
A brief overview of the setup procedure for the SJ-M Series is provided below.
1. Selecting an operation mode
Use the operation mode selector switch to change the operation mode.
Operation mode selection
1. Operation mode selection
Select an operation mode.Select the operation
mode using the operation mode selector switch.
Settings adjustment
2. Settings adjustment
Change the settings for the SJ-M400.
Ion balance adjustment
3. Ion balance adjustment
The zero point, the point for reference for the I.C.C.
function, can be adjusted.
(* The zero point should only be adjusted when
necessary.)
S
G
T
SPOT MODE
GUN MODE
TEST MODE
SPOT MODE
This mode is used to continuously perform static
elimination by installing the static elimination head within
a device.
The valve output of the terminal (2) turns ON/OFF while
the terminals (3) and (6) are shorted out.
"Timing Charts" (page 10)
Static elimination is turned ON/OFF in the cycle specified
in the "Valve control frequency setting".
GUN MODE
This mode is used to frequently turn ON/OFF static
elimination by installing the static elimination head within
an air gun.
TEST MODE
This is the output terminal test mode. Alarm signals such
as ion level alarm and condition alarm signals are output
and static elimination stops.
* Switching the operating mode will reboot the SJ-M Series.
3-1
SJ-M Series Operations
2. Changing settings
■ Setting adjustment overview
This section provides details regarding settings and a brief overview of the setup procedure used for
changing operation modes on the SJ-M Series.
Setting items
Run mode
Setup mode
[Setting items]
[Detailed settings]
Either lights up
Normal operation state.
Select setting items.
Select detailed settings.
Blink alternately
Blink alternately fast
Hold down
and
simultaneously
for at least 1
second.
Hold down
for at least
1 second.
Press
for a
short time.
Press
for a
short time.
Run mode
Setup mode
[Setting items]
[Detailed settings]
Ion level alarm
sensitivity setup
Sensitivity: High
Sensitivity: Medium
Sensitivity: Low
Sensitivity: None
Sensitivity: High
Sensitivity: Medium
Sensitivity: Low
Sensitivity: None
Condition alarm
sensitivity setup
I.C.C. ON
I.C.C. OFF
High:11.5Hz
Medium:5.8Hz
Low:3.8Hz
I.C.C. ON/OFF
setting
Valve control
frequency setting
Initialization of
settings
3-1
SJ-M Series Operations
■ Procedure for changing settings
The procedure for changing settings for the SJ-M Series is as follows.
1
Check that the unit is in Run mode.
2
Hold down
and
for at least one second to enter
setting item selection in Setup mode.
3
Press
or
to
select
the
item
to
be
set.
For details on items, see "Setting items" on page 7.
4
Press
to select detailed Setup mode settings for
adjustment.
Either lights up
[Run mode]
Either "BALANCE" or "ION" lights up.
Tip
[Setup mode]
Blink alternately
"BALANCE" and "ION" blink alternately.
Tip
[Setup mode]
Blink alternately fast
"BALANCE" and "ION" blink alternately fast.
Tip
3-1
SJ-M Series Operations
5
Press
or
to
select
the
item
to
be
set.
For details on items, see "Setting items" on page 7.
6
Press
to return to setting item selection in Setup mode.
To change other items, repeat the procedure from steps 4 to 6.
7
Hold down
for at least one second to return to Run mode.
Setting adjustment is now complete.
[Setup mode]
Blink alternately