Warranties and disclaimers – KEYENCE SJ-F300 Series User Manual
Page 14
13
2
Table of Indicated States
Description
The power indicator on the Controller Unit and
three center LEDs of the monitor on the Static
Elimination Blower Unit blink in red.
During an alarm (level 1)
The power indicator on the Controller Unit and
three center LEDs of the monitor on the Static
Elimination Blower Unit blink in red under the
following conditions.
Remove the cause of alarm condition, and then
press and hold and on the Static
Elimination Blower Unit for about three seconds
simultaneously.
The alarm condition will be cancelled. You can
turn on the power.
Cause of alarm condition
· The lock switch on the Static Elimination Blower
Unit is disengaged.
· The rear cover or the front cover of the Static
Elimination Blower Unit is not properly attached.
During an alarm (level 2)
The power monitor LEDs, ion level alarm indicator,
condition alarm indicator on the Controller Unit,
and all the monitor LEDs on the Static Elimination
Blower Unit blink in red under the following
conditions.
Remove the cause of alarm condition to cancel the
alarm by following the instructions below.
If the alarm is output repeatedly, please contact
your nearest KEYENCE sales office.
Cause of alarm condition
· Discharged abnormally
· Internal memory value trouble
· Electrode unit not attached
· Fan trouble
How to cancel the alarm
· When discharged abnormally, turn on the power
again.
· When some trouble occurred in the internal
memory, press and hold and for about
three seconds.
Ion level alarm indicator blinks in red.
Ion level alarm
The ion level alarm indicator blinks in red when the
ion level decreases lower than the setting value.
Lit State
The power indicator, ion level alarm indicator,
condition alarm indicator on the Controller Unit,
and all the monitor LEDs on the Static Elimination
Blower Unit blink in red.
2
Table of Indicated States
Description
During an alarm (level 3)
The power indicator, ion level alarm indicator,
condition alarm indicator on the Controller Unit, and
all the monitor LEDs of the Static Elimination Blower
Unit blink in red and the power supply to the Static
Elimination Blower Unit is stopped under the
following conditions.
Remove the cause of alarm condition to cancel the
alarm by following the instructions below.
Cause of alarm condition
· Excessive number of Static Elimination Blower
Units connected
· Lead broken or disconnected
· Internal circuit damaged
How to cancel the alarm
· Take appropriate measures against excessive
number of Static Elimination Blower Units
connected and lead broken or disconnected,
and then turn on the power again.
* When the internal circuit has been damaged,
please contact your nearest KEYENCE sales
office.
Lit State
The power indicator, ion level alarm indicator,
condition alarm indicator on the Controller Unit,
and all the monitor LEDs on the Static Elimination
Blower Unit blink in red.
WARRANTIES AND DISCLAIMERS
(1) KEYENCE warrants the Products to be free of defects in materials and workmanship for a period of one (1)
year from the date of shipment. If any models or samples were shown to Buyer, such models or samples were
used merely to illustrate the general type and quality of the Products and not to represent that the Products
would necessarily conform to said models or samples. Any Products found to be defective must be shipped to
KEYENCE with all shipping costs paid by Buyer or offered to KEYENCE for inspection and examination. Upon
examination by KEYENCE, KEYENCE, at its sole option, will refund the purchase price of, or repair or replace
at no charge any Products found to be defective. This warranty does not apply to any defects resulting from
any action of Buyer, including but not limited to improper installation, improper interfacing, improper repair,
unauthorized modification, misapplication and mishandling, such as exposure to excessive current, heat,
coldness, moisture, vibration or outdoors air. Components which wear are not warranted.
(2) KEYENCE is pleased to offer suggestions on the use of its various Products. They are only suggestions, and it
is Buyer's responsibility to ascertain the fitness of the Products for Buyer’s intended use. KEYENCE will not be
responsible for any damages that may result from the use of the Products.
(3) The Products and any samples ("Products/Samples") supplied to Buyer are not to be used internally in
humans, for human transportation, as safety devices or fail-safe systems, unless their written specifications
state otherwise. Should any Products/Samples be used in such a manner or misused in any way, KEYENCE
assumes no responsibility, and additionally Buyer will indemnify KEYENCE and hold KEYENCE harmless from
any liability or damage whatsoever arising out of any misuse of the Products/Samples.
(4)
OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE PROVIDED WITH NO OTHER
WARRANTIES WHATSOEVER. ALL EXPRESS, IMPLIED, AND STATUTORY WARRANTIES, INCLUDING,
WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR
PURPOSE, AND NON-INFRINGEMENT OF PROPRIETARY RIGHTS, ARE EXPRESSLY DISCLAIMED. IN
NO EVENT SHALL KEYENCE AND ITS A FFILIATED ENTITIES BE LIABLE TO ANY PERSON OR ENTITY
FOR ANY DIRECT, INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES
(INCLUDING, WITHOUT LIMITATION, ANY DAMAGES RESULTING FROM LOSS OF USE, BUSINESS
INTERRUPTION, LOSS OF INFORMATION, LOSS OR INACCURACY OF DATA, LOSS OF PROFITS,
LOSS OF SAVINGS, THE COST OF PROCUREMENT OF SUBSTITUTED GOODS, SERVICES OR
TECHNOLOGIES, OR FOR ANY MATTER ARISING OUT OF OR IN CONNECTION WITH THE USE OR
INABILITY TO USE THE PRODUCTS, EVEN IF KEYENCE OR ONE OF ITS AFFILIATED ENTITIES WAS
ADVISED OF A POSSIBLE THIRD PARTY’S CLAIM FOR DAMAGES OR ANY OTHER CLAIM AGAINST
BUYER. In some jurisdictions, some of the foregoing warranty disclaimers or damage limitations may not
apply.
BUYER'S TRANSFER OBLIGATIONS:
If the Products/Samples purchased by Buyer are to be resold or delivered to a third party, Buyer must provide
such third party with a copy of this document, all specifications, manuals, catalogs, leaflets and written
information provided to Buyer pertaining to the Products/Samples.
E 1110-2
Copyright (c) 2009 KEYENCE CORPORATION. All rights reserved.
10106E 1120-2 96M10106
Printed in Japan