2 specifications, 3 external dimensions, Specifications – KEYENCE SJ-F300 Series User Manual

Page 12: External dimensions, Body, Mounting fixture

background image

11

5-2

Specifications

Controller Unit/Static Elimination Blower Unit

AC adapter

Static elimination stop input

Alarm output

Ion level alarm output

Condition alarm output

Power voltage

Current consumption

Operating ambient temperature

Operating ambient humidity

Static Elimination Blower Unit

Controller Unit

Voltage application method

Applied voltage

Ion balance control method

Static elimination time

*1

Ion balance

*1

Max. fan speed

*2

Max. blow rate

Ozone concentration

Control input

Variable DC

±7000 V max.

I.C.C. method

3.1 m

3

/min

0.005 ppm max.

NPN open collector or no-voltage contact signal

NPN open collector

100 mA (40 V max.)

24 VDC±10%

1.2 A max.

0 to +50°C

35 to 65%RH (condensation not allowed)

Approx. 620 g

Approx. 320 g

Approx. 2 sec

±5 V

0.8 m/s

Approx. 0.7 sec

±10 V

3.5 m/s

Model

Control output

Rating

Environmental
resistance

Weight

Controller Unit

Static Elimination Blower Unit

SJ-F300

*1 Values obtained by measurement 300 mm from the front of the Static Elimination Blower Unit

(SJ-F030: Blow rate min./SJ-F035: Blow rate max.)

*2 Values obtained by measurement 300 mm from the front of the Static Elimination Blower Unit

SJ-F030 (Wide type)

SJ-F035 (High speed type)

Rated input

Rated output

Operating ambient temperature

Operating ambient humidity

* The power cable supplied with SJ-U2 is 125V rated power voltage.

100 to 240 VAC (50/60 Hz)

24 VDC 2.65 A

0 to +35°C

20 to 80% (condensation not allowed)

Approx. 250 g

Model

Rating

Environmental
resistance

Weight

SJ-U2

5-3

External Dimensions

Body

When the Controller Unit and the Static Elimination Blower Unit integrated

Controller Unit

(139)

22.6

SJ-F030 67
SJ-F035 72

103.7

30°

(109)

(50)

45

φ

15

120

(Fixing part 121)

140.7

211.7

(2)

37.8

120

103.7

35.9

φ6 Cable length 300 mm

Min. bend radius 15

2-M4 to depth 3

φ

15

φ

15

31

41.7

30.7

(2)

(62)

5-3

External Dimensions

Static Elimination Blower Unit

Mounting fixture

106

(5)

2x2 M4 to depth 6

12.2

11.7

45

64.5

SJ-F030 61.5
SJ-F035 66.5

5.5

(50)

1

(121.6)

158

87

120

(Fixing part 121)

R35

4.5

3-M6

80°

30°

26

121

φ11

2.3

35

50

4

110

138

70

10

4.5

5.5

17

t = 3.2

60

4.5

98.5

83

5.5

40

40°

Mounting fixture A (OP-78476)

Mounting fixture B (OP-78477)

5-3

External Dimensions

Extension cable (SJ-C * J)

Extension cable (SJ-C * P)

AC adapter (SJ-U2)

* For details of the AC cable, contact the KEYENCE sales office in your district.

6 mm dia. cable length

SJ-C2J 2 m

SJ-C5J

5

m

SJ-C10J

10

m

49

φ

15.5

51

φ

15

6 mm dia. cable length

SJ-C02P 0.2 m

SJ-C2P

2 m

SJ-C5P

5 m

SJ-C10P

10 m

51

51

φ

15

φ

15

(37.5)

7

ш16

(10.3)

(16.3)

(12.5)

(14)

28

ш3.5

1800

114.5

50.5