2 specifications, 3 external dimensions, Specifications – KEYENCE SJ-F300 Series User Manual
Page 12: External dimensions, Body, Mounting fixture
11
5-2
Specifications
■ Controller Unit/Static Elimination Blower Unit
■ AC adapter
Static elimination stop input
Alarm output
Ion level alarm output
Condition alarm output
Power voltage
Current consumption
Operating ambient temperature
Operating ambient humidity
Static Elimination Blower Unit
Controller Unit
Voltage application method
Applied voltage
Ion balance control method
Static elimination time
*1
Ion balance
*1
Max. fan speed
*2
Max. blow rate
Ozone concentration
Control input
Variable DC
±7000 V max.
I.C.C. method
3.1 m
3
/min
0.005 ppm max.
NPN open collector or no-voltage contact signal
NPN open collector
100 mA (40 V max.)
24 VDC±10%
1.2 A max.
0 to +50°C
35 to 65%RH (condensation not allowed)
Approx. 620 g
Approx. 320 g
Approx. 2 sec
±5 V
0.8 m/s
Approx. 0.7 sec
±10 V
3.5 m/s
Model
Control output
Rating
Environmental
resistance
Weight
Controller Unit
Static Elimination Blower Unit
SJ-F300
*1 Values obtained by measurement 300 mm from the front of the Static Elimination Blower Unit
(SJ-F030: Blow rate min./SJ-F035: Blow rate max.)
*2 Values obtained by measurement 300 mm from the front of the Static Elimination Blower Unit
SJ-F030 (Wide type)
SJ-F035 (High speed type)
Rated input
Rated output
Operating ambient temperature
Operating ambient humidity
* The power cable supplied with SJ-U2 is 125V rated power voltage.
100 to 240 VAC (50/60 Hz)
24 VDC 2.65 A
0 to +35°C
20 to 80% (condensation not allowed)
Approx. 250 g
Model
Rating
Environmental
resistance
Weight
SJ-U2
5-3
External Dimensions
■ Body
When the Controller Unit and the Static Elimination Blower Unit integrated
Controller Unit
(139)
22.6
SJ-F030 67
SJ-F035 72
103.7
30°
(109)
(50)
45
φ
15
120
(Fixing part 121)
140.7
211.7
(2)
37.8
120
103.7
35.9
φ6 Cable length 300 mm
Min. bend radius 15
2-M4 to depth 3
φ
15
φ
15
31
41.7
30.7
(2)
(62)
5-3
External Dimensions
Static Elimination Blower Unit
■ Mounting fixture
106
(5)
2x2 M4 to depth 6
12.2
11.7
45
64.5
SJ-F030 61.5
SJ-F035 66.5
5.5
(50)
1
(121.6)
158
87
120
(Fixing part 121)
R35
4.5
3-M6
80°
30°
26
121
φ11
2.3
35
50
4
110
138
70
10
4.5
5.5
17
t = 3.2
60
4.5
98.5
83
5.5
40
40°
Mounting fixture A (OP-78476)
Mounting fixture B (OP-78477)
5-3
External Dimensions
■ Extension cable (SJ-C * J)
■ Extension cable (SJ-C * P)
■ AC adapter (SJ-U2)
* For details of the AC cable, contact the KEYENCE sales office in your district.
6 mm dia. cable length
SJ-C2J 2 m
SJ-C5J
5
m
SJ-C10J
10
m
49
φ
15.5
51
φ
15
6 mm dia. cable length
SJ-C02P 0.2 m
SJ-C2P
2 m
SJ-C5P
5 m
SJ-C10P
10 m
51
51
φ
15
φ
15
(37.5)
7
ш16
(10.3)
(16.3)
(12.5)
(14)
28
ш3.5
1800
114.5
50.5