beautypg.com

Key lock, Default mode settings (initialization), Specifications – KEYENCE AP-V42A(P) User Manual

Page 5: Error displays and corrective actions, Warranty, Key lock 16. specifications

background image

5

17. Error Displays and Corrective Actions

Error displays during normal operation

• No difference in sensitivity

(during 2 point tuning/AI
tuning/active tuning).

• There is an applied pressure

of

±5 % of F.S. during ambient

pressure compensation.

• There is no sensor head

connected.

• The connection to the sensor head

is broken.

• An excess current is flowing to the

control output.

• Reading is falling below

(exceeding) configuration/display
pressure range.

• Reading is exceeding (falling

below) configuration/display
pressure range.

• The count value exceeds 19999.

• Zero shift timing and threshold

settings are not optimum for
suction detection.

• There were not at least 2 shift

inputs received during AI
tuning/active tuning.

• The pressure for step 2) of the AI

tuning procedure is not higher

Adjust the air pressure device so that
there will be a difference in sensitivity.

Revert to ambient pressure and
readjust sensitivity.

Verify that a sensor head is connected
and turn the power on again.

Check whether the connection to the
sensor head is broken and turn the
power on again.

Check the load and return it to the
rated range.

Return the pressure to the rated
pressure range.

• Return the pressure to the rated

pressure range.

• Reset the count value.

The difference in pressures for a
target object being present and
absent for zero shift timing is too
large. Adjust the settings.

Repeat the active tuning procedure
so that at least 2 shift inputs are
received.

Check the pressure readings when the
target object is present and when it is

Display

Cause

Solution

* Contact KEYENCE for information about error displays other than those described

above.

*1 AP-V41/V41P only.
*Press

button 5 times while holding down the

button to

return the sensor to its default configuration.

Detection mode

F-1 general-purpose mode

Operating mode

Standard

N.O./N.C. switching

N.O./N.O.

Analog/zero shift

*1

Zero shift

Chatter prevention

2.5 msec

Power-save

Standard

The sensor ships with the following configuration.

15. Default Mode Settings (Initialization)

Key lock disables operation of the sensor's keys.
When the

button is pressed for 3 seconds or more while the

but-

ton is being held down, the

display will flash and the key lock

feature will be engaged.
This feature disables changes to sensor settings but allows switching of
the display.
*The same key combination will deactivate the key lock feature.

14. Key Lock

16. Specifications

Sensor head

Amplifier

*1 AP-V41AP/42AP are PNP output types.
*2 The amplifier type with the letter “A” attached on its tail has the count value dis-

play function. Also, the amplifier’s response toward the signals from the head is
faster.

*3 0.1% of F.S. when high-resolution mode is selected.
*4 Max. 20 mA when using expansion units.

Model
Rated pressure
range

Pressure resistance

Adaptive fluids

Pressure type

Temperature
characteristics

Pressure port

Ambient temperature

Relative humidity

Vibration

Shock Resistance

Housing material

Weight

AP-41/41M

AP-43

AP-44

AP-48

0 to

0 to

+101.3 to

-101.3 to

-101.3 kPa

1.000 MPa

-101.3 kPa

+101.3 kPa

500 kPa

1.5 MPa

500 kPa

500 kPa

Air, non-corrosive gasses

Gauge pressure

Within

±2 % of F.S. (at 25 °C)

Within

(in temperature range of 0 to 50

°C)

±2 % of F.S.

M5 male screw

PT1/8

(AP-41M is M3 male screw)

0 to +50

°C (No freezing)

35 to 85 % RH (No condensation)

10 to 55 Hz, compound amplitude 1.5 mm, 4 hours for each of XYZ axes

1,000 m/s

2

, 10 times for each of XYZ axes, total 60 times

Case: PBT; Screws: SUS303

Case: PBT;

Screws: SUS303

7 g (not including cables) / 70 g (including

35 g/98 g

3-m cable) (4.8 g / 67.8 g for AP-41M)

Environmental resistance

*1 *2

Differential

pressure

Model

Head combination

Power supply voltage

Current

consumption

Display method

Configuration/display range

Operating status indicators

Standard mode

High-resolution mode

Repeatability

Hysteresis
Display temperature
characteristics

Response (chatter
prevention feature)

Zero shift input

Control

output

Analog output

Ambient temperature

Relative humidity

Vibration

Housing material

Weight

AP-V41A/V41AP/V42A/V42AP

AP-41M

AP-41

AP-43

AP-44

AP-48

12 to 24 VDC

±10% Ripple (P-P) 10% max.

4.5 digit 7 segment LED (4.5 mm character height; red)

AI indicator (green) Display cycle: 10 times/second

-15 to +110 % of F.S.

Red LED x 2 (supports control output 1 / control output 2)

0.1 kPa

0.1 kPa

0.001 MPa

0.1 kPa

0.1kPa

0.01 kPa

0.01 kPa

0.1 kPa

0.02 kPa

0.02 kPa

±0.2 % of F.S.

Variable (standard 0.5% of F.S.)

±1% of F.S. max.

Selectable from 1, 2.5, 5, 100, 500 ms

(1 ms during high-speed mode operation)

With contacts, without contacts Input time 2 ms or greater

(With AP-V41A(P), switchable with analog output.)

NPN open collector max. 100 mA

(40 V max.) residual voltage 1 V max., 2 outputs (NO/NC switchable)

PNP open collector max. 100 mA (30 V max.)

residual voltage 1 V max., 2 outputs (NO/NC switchable)

1to 5 V Output impedance 1 k

Ω max.

(Included on AP-V41A (P) only. Switchable with zero shift input.)

0 to +50

°C (No freezing)

35 to 85 % RH (No condensation)

10 to 55 Hz, compound amplitude 1.5 mm, 2 hours for each of XYZ axes

Main unit cover: Polycarbonate

Approx. 80 g (including 2-m cable) Approx. 35 g(not including cables)

Rating

Resolution

Environmental

resistance

*1 *2

*3

*4

AP-V41A

AP-V42A

AP-V41AP

AP-V42AP

Output type

Supplied voltage

Eco mode

Normal

720 mW(60mA) 840 mW(70mA) max. 960 mW(40mA) 1200 mW(50 mA) max.

480 mW(40 mA) 600 mW(50 mA) max. 720 mW(30mA) 960 mW(40 mA) max.

12 V operation

24 V operation

NPN

PNP

NPN

PNP

(1) KEYENCE warrants the Products to be free of defects in materials and workmanship for

a period of one (1) year from the date of shipment. If any models or samples were
shown to Buyer, such models or samples were used merely to illustrate the general type
and quality of the Products and not to represent that the Products would necessarily
conform to said models or samples. Any Products found to be defective must be
shipped to KEYENCE with all shipping costs paid by Buyer or offered to KEYENCE for
inspection and examination. Upon examination by KEYENCE, KEYENCE, at its sole
option, will refund the purchase price of, or repair or replace at no charge any Products
found to be defective. This warranty does not apply to any defects resulting from any
action of Buyer, including but not limited to improper installation, improper interfacing,
improper repair, unauthorized modification, misapplication and mishandling, such as
exposure to excessive current, heat, coldness, moisture, vibration or outdoors air.
Components which wear are not warranted.

(2) KEYENCE is pleased to offer suggestions on the use of its various Products. They are

only suggestions, and it is Buyer’s responsibility to ascertain the fitness of the Products
for Buyer’s intended use. KEYENCE will not be responsible for any damages that may
result from the use of the Products.

(3) The Products and any samples ("Products/Samples") supplied to Buyer are not to be

used internally in humans, for human transportation, as safety devices or fail-safe
systems, unless their written specifications state otherwise. Should any Products/
Samples be used in such a manner or misused in any way, KEYENCE assumes no
responsibility, and additionally Buyer will indemnify KEYENCE and hold KEYENCE
harmless from any liability or damage whatsoever arising out of any misuse of the
Products/Samples.

(4) OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE PROVIDED

WITH NO OTHER WARRANTIES WHATSOEVER. ALL EXPRESS, IMPLIED, AND
STATUTORY WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE
WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE,
AND NON-INFRINGEMENT OF PROPRIETARY RIGHTS, ARE EXPRESSLY
DISCLAIMED. IN NO EVENT SHALL KEYENCE AND ITS A FFILIATED ENTITIES
BE LIABLE TO ANY PERSON OR ENTITY FOR ANY DIRECT, INDIRECT,
INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES (INCLUDING,
WITHOUT LIMITATION, ANY DAMAGES RESULTING FROM LOSS OF USE,
BUSINESS INTERRUPTION, LOSS OF INFORMATION, LOSS OR INACCURACY OF
DATA, LOSS OF PROFITS, LOSS OF SAVINGS, THE COST OF PROCUREMENT
OF SUBSTITUTED GOODS, SERVICES OR TECHNOLOGIES, OR FOR ANY
MATTER ARISING OUT OF OR IN CONNECTION WITH THE USE OR INABILITY TO
USE THE PRODUCTS, EVEN IF KEYENCE OR ONE OF ITS AFFILIATED ENTITIES
WAS ADVISED OF A POSSIBLE THIRD PARTY’S CLAIM FOR DAMAGES OR ANY
OTHER CLAIM AGAINST BUYER.
In some jurisdictions, some of the foregoing
warranty disclaimers or damage limitations may not apply.

BUYER’S TRANSFER OBLIGATIONS:

If the Products/Samples purchased by Buyer are to be resold or delivered to a third
party, Buyer must provide such third party with a copy of this document, all
specifications, manuals, catalogs, leaflets and written information provided to Buyer
pertaining to the Products/Samples.

E 1110-2

WARRANTY

Copyright (c) 2003 KEYENCE CORPORATION. All rights reserved.

1373E 1111-2 96M1373 Printed in Japan

This manual is related to the following products: