Sensor configuration – KEYENCE AP-V42A(P) User Manual
Page 3
3
+
+
After 4 sec
of no key
operation.
Peak hold
Press for 3 sec or more.
■ Toggling the
display
■ Manual configuration
■ Mode
configuration
Increase the
setting.
Decrease the
setting.
Detection mode
Operating mode
Standard
High-resolution mode
High-speed
Zero shift input
Analog output
N.O./N.C.
N.O.
N.O.
N.C.
N.C.
N.O.
N.C.
N.C.
N.O.
Control
output 1
Control
output 2
2.5 msec
5
msec
100 msec
500 msec
General-purpose mode
Variable hysteresis mode
Window mode
Application mode 1
Application mode 2
Analog/zero shift
Standard
Eco operation
Power-save
Chatter prevention
Sets response time.
AP-
V42A(P)
only
When
operating
mode is
Bottom hold
• Two-point tuning
• AI tuning
• Active tuning
* High-speed mode provides a 1-ms
high-speed response.
• N.O. = normal open.
• N.C. = normal close.
Reference
value*1
Current
value
Count
value*2
Settings are manually
configured. The
display changes for
each mode.
* Toggling the display
of settings (see the
diagram below).
* The sensor must be
manually configured
to operate in either
F-3 or A-2 mode.
* The sensor cannot
be manually
configured during
the count value
display.
*1 The reference value is the
pressure value when zero
shift input is received and is
replaced only when zero
shift input is selected.
*2 The count value indicates the
number of output times of
Output 1. Once the value
exceeds 19999, it is
displayed as FFFF. The count
value is reset with one of the
following operations:
Press and hold the
+ button.
Power-on
Initialization
Current value
Reference value
Count value
Hold value
10. Sensor Configuration
■ Toggling the display of settings
●
General-purpose mode/F1
●
Variable hysteresis mode/F-2
●
Window mode/F-3
●
Application mode 1/A-1
●
Application mode 2/A-2
■ Two-point tuning (F-1/F-2)
The sensor is made to detect the pressures when the target object is
present and then absent for confirmation of target suction pick-up, and
the intermediate value is used.
Control output 1 configuration: When P1 (H1) is selected on the settings
display.
Control output 2 configuration: When P2 (H2) is selected on the settings
display.
Flashes
for 3 sec.
Setting
Target object
present
Target object
absent
■ AI tuning/Active tuning (A-1)
See Section 12.
Note:• Press the mode button (
) for at least 3 seconds to return to the
current value/reference value/count value/hold value display from
other menu displays.
• Press the left side
on the manual adjustment button (
)
while holding down the mode button (
) to return to the previous
display.
• The current value will be displayed based on the ambient pressure
conditions prevalent at that time without regard to zero shift input
when the P2 setting display is selected for A-1 mode or when the
HI and Lo setting displays are selected for A-2 mode.
• The sensor must be manually configured to operate in either F-3
or A-2 mode. The SET button (
) cannot be used with either of
these modes.