KEYENCE AP-V42A(P) User Manual
Instruction manual, Ap-v41a(p)/v42a(p), Wire-saving ai digital pressure sensor
1
96M1373
3. Sensor Installation
4. Additional Amplifier installation
A single AP-V41A(P) sensor can be expanded
with the following number of slave units:
Up to 8 units
AP-V42A/LV-22A/12SA
Up to 16 units FS-T2/M2/V12/V22/PS-T2/ES-M2
2. Part Names
Operating status indicators
Set button
Display
Manual adjustment button
Expansion
protective cover
Mode button
Dust cover
Expansion
connector
Sensor head connector
Output 1
Output 2
AP-V41A(P)
AP-V42A(P)
2
1
5. Sensor Head Installation
AI
Insert until it
clicks into place.
3
2
1
M3 screws
About
25 mm
About
25 mm
Connector
body
Connector
cover
Connector
lock
Orange
Brown Blue
Gray
Pressure
connection
●
2 end units (included
with AP-V42A(P)
●
1 sensor head
connector
●
1 expansion seal
(included with
AP-V42A(P)
●
1 instruction
manual
●
1 mounting bracket
(included with AP-
V41A(P))
1) Cut the cable to an appropriate
length and strip away about 25
mm of the outermost insulation.
Note: It is not necessary to
remove insulation from the
core wires.
2) Insert the cables after aligning
them with the colors on the seal
on top of the connector body.
3) Press together the body and the
connector cover into which the
cables were inserted to make a
connection (use a pair of pliers
or similar tool to press them to-
gether).
4) Insert the sensor head connec-
tor into the hole on the front of
the amp unit.
To remove the connector, de-
press the connector lock and
pull it out.
●
Installation on a DIN track
1) Align the hook on the bottom
of the sensor to the DIN track
as shown below. Lower the sen-
sor in the direction indicated by
➁
while pressing on the sensor
in the direction indicated by
➀
.
2) When removing the sensor, lift
the sensor as shown in
➂
while
pushing on the sensor in the di-
rection indicated by
➀
.
●
Installation using the included
mounting bracket (AP-
V41A(P)).
1) Remove the AP-V41A(P)’s
expansion protective cover.
2)Install the amps onto the DIN
track one at a time.
3) Insert the 2 hooks on each slave
unit into the groove on the AP-
V41A(P) until they click into
place.
4) Attach an end unit to each side
of the chain of amp units.
Sandwich the amps securely
between the end units and use
a Phillips head screwdriver to
tighten the screws on the top of
the end units (2 screws for each
unit).
* The same applies to the PNP type of the
respective models.
Wire-saving AI Digital
Pressure Sensor
AP-V41A(P)/V42A(P)
Instruction Manual
1. Safety Precautions
WARNING
●
Do not use this product in safety circuits such as those designed to
protect human workers.
●
This product does not employ an explosion-proof construction. Do not
use it in the presence of flammable gasses, liquids, or powders.
●
This is a direct current power supply type sensor. Application of an
alternating current may result in explosion or fire.
■ Accessories
Document Outline
- 1. Safety Precautions
- 2. Part Names
- 3. Sensor Installation
- 4. Additional Amplifier installation
- 5. Sensor Head Installation
- 6. Connection Diagram
- 7. Precautions for Safe Use
- 8. About Sensor Head Installation
- 9. Detection Mode Operation
- 10. Sensor Configuration
- 11. Explanation of Features
- 12. AI Tuning/Active Tuning (A-1)
- 13. Ambient Pressure Compensation
- 14. Key Lock
- 15. Default Mode Settings (Initialization)
- 16. Specifications
- 17. Error Displays and Corrective Actions
- WARRANTY