Connecting the unit to external devices, Communication terminal block – KEYENCE DL-RS1A/GT-70A User Manual
Page 7
5
Connecting the Unit to Sensor Amplifiers
■ Connecting the unit to panel mount sensor amplifiers
1
Connect DL-RS1A to the sensor amplifiers using the optional expansion cable (OP-35361).
2
Remove the sensor amplifier connector with pliers (for DIN rail mounting when using with panel
mounted sensor amplifiers) from DL-RS1A unit and install the expansion connector cover
supplied with the unit.
■ Connecting to a large display type sensor amplifier
1
Connect the sensor amplifier to the RS-232C Communication Unit DL-RS1A using the optional
expansion cable (OP-35361).
2
Detach the sensor amplifier connector (DIN rail mount type) of the RS-232C Communication
Unit DL-RS1A with pliers and mount the attached expansion connector.
• Make sure you securely connect the expansion cable while the unit is turned
off. Turning the power on when the cable is not inserted straight or firmly
connected may damage the unit.
• Removing or inserting the cable while the power is on may damage the unit.
• Turn OFF the power before connecting the expansion cable and connect
securely. Diagonal or otherwise improper insertion may damage the
equipment.
• Inserting or pulling the cable when the power is turned ON may damage the
equipment.
Remove the
protection sticker
Expansion cable (cable length: 300 mm)
(OP-35361)
NOTICE
Sensor amplifier connector
(for DIN rail mounting type)
Expansion connector cover
Detach the
protection sticker
Expansion cable (cable length: 300mm)
Detach the
protection sticker
NOTICE
Sensor amplifier connector
(for DIN rail mount type)
Expansion connector cover
Connecting the Unit to External Devices
Communication Terminal Block
You can connect external devices such as a PC or PLC to the communication terminal block of
DL-RS1A via the communication cables.
■ Terminal connection
*
Recommended communication cable
KPEV-SP(1P) wire with balanced type twisted shield (strand wire)
Nominal cross-section area 0.16mm
2
(AWG25) min.
A terminal cover is attached to the terminal block.
The terminal cover must be placed over the terminal block when you finish connecting the cables.
The terminals for SG (Nos. 1, 4, and 5) are used in common with the blue wire of the sensor amplifier
main unit.
●
Crimp-type terminal
Use the Y or round terminal for wiring to the I/O terminal.
Use the Y or round terminal with the following dimensions.
Y terminal
Round terminal
SG
RD
SD
SG
SG
DRQ
Communication cable
To external device
KPEV-SP(1P) wire with balanced
type twisted shield (strand wire)
Terminal No.
Terminal
Description
1
SG
Connects to the shielded wire of the communication cable.
The terminals for SG (Nos. 1, 4, and 5) are internally short-circuited.
2
RD (input)
Connects to the SD terminal of an external device via a communication cable.
3
SD (output) Connects to the RD terminal of an external device via a communication cable.
4
SG
The terminals for SG (Nos. 1, 4, and 5) are internally short-circuited.
5
SG
The terminals for SG (Nos. 1, 4, and 5) are internally short-circuited.
6
DRQ (input)
When there is a short-circuit between DRQ and SG, the sensor amplifier data is
transmitted even without a command from the external device.
Point
Reference
Excerpted from dimensions of the Y terminal areas
B: Outer size of Y area
d: Width of inner Y area
(joint area with screw)
Applicable dimension
B: 6mm max.
d: 3.2mm min.
Excerpted from dimensions of the round terminal areas
B: Outer diameter
d: Inner diameter
(joint area with screw)
Applicable dimension
B: 6mm max.
d: 3.2mm min.
B
B
φd
d