Adjustment response speed, Sensitivity, Zero adjustment – KEYENCE LB-70(W) Series User Manual
Page 10

10
2 ms
60 ms
0.15 ms
0.7 ms
20 ms
500 ms
For measurements requiring
high accuracy.
Normal setting for detecting
and measuring targets.
For detecting targets moving
at high speed on the production
line. Detects eccentricity and
deflection of revolving targets.
BLACK
AUTO
WHITE
Suitable for black targets.
KEYENCE's original auto gain
function instantly assesses the
gain level, which varies according
to conditions such as color and
material, for optimum measurement.
Suitable for white targets.
4
-4
O-ADJ
V
Panel meter
Distance
Analog output
voltage
Reference
position
4
-4
SPAN
Panel meter
Distance
10 mm
Analog output
voltage
V
Reference
position
LB-11
LB-12
40 mm
ADJUSTMENT
Response speed
Select the desired response speed using the response speed selector
switch.
Sensitivity
Select the appropriate sensitivity using the sensitivity selector switch.
Zero adjustment
1. When the target is displaced from the reference position, the analog
output voltage may deviate from the zero point. The 0-ADJ adjust-
ment trimmer can be used to adjust the reading to the zero point.
2. Confirm that the value of the output voltage is in proportion to the
displacement of the target. If not, adjust the output voltage with the
SPAN adjustment trimmer.
3. Confirm that the analog output voltage is 0 v at the reference position.
If not, repeat the above adjustment procedures.
LB-70 (W)