Installation, Controller, Sensor head – KEYENCE EX-500(W) Series User Manual
Page 6
6
INSTALLATION
Controller
The controller can be mounted to a DIN rail. When mounting or
dismounting the controller, pull the claws located at the bottom of
the controller in the direction shown by the arrows. Also, the
controller can be mounted with screws by pulling out the fittings.
Sensor head
■ Connecting to/disconnecting from the controller
• Plug the sensor head cable into
the connector of the controller until
it clicks. (When connecting an
extension cable to the controller or
the sensor head, follow the same
procedure.)
• When disconnecting the plug, hold
it by the sleeve and pull it out as
shown on the right.
When connecting and disconnect-
ing the plug, be sure to hold it by
the sleeve. If you forcefully pull on
the cable, the cable may break off
from the plug.
■ Mounting
Nut tightening position
Tighten the nut away from the tip of
the metal case as shown on the right.
Torque values
Tighten the nut according to the
torque values given in the table
below.
EX-008
EX-016
EX-022
10 Nm
20 Nm
30 Nm
(approx. 100 kgf-cm) max. (approx. 200 kgf-cm) max. (approx. 300 kgf-cm) max.
■ Flush-mounting
The diagram and table below shows the dimensions to use when
flush-mounting a sensor head onto a metal plate.
A (mm)
B (mm)
EX-008
20
11
EX-016
45
20
EX-022
60
25
When mounted with screws
When mounted on DIN rail
Incorrect
Correct
3mm min
øA
B