Specifications – KEYENCE EX-500(W) Series User Manual
Page 13
13
SPECIFICATIONS
Type
Threaded, non-shielded type
Size
M8
M8
M16
M22
Sensor head
EX-008
EX-008
EX-016
EX-022
Controller
EX-501(W)
EX-502(W)
EX-505(W)
EX-510(W)
Measuring range
0 to 1 mm
0 to 2 mm
0 to 5 mm
0 to 10 mm
Output voltage
0 to 5V
Output impedance
100 Ω
Output current
4 to 20 mA (Applicable load: 0 to 350 Ω)
Resolution
0.03 % of F.S. (RESPONSE = 3, 4)
Response time
0.1 ms (RESPONSE = 1)
(Response mode)
1 ms (RESPONSE = 2)
10 ms (RESPONSE = 3)
100 ms (RESPONSE = 4)
Linearity
±0.3 % of F.S. (RESPONSE = 2, 3, 4)
Auto-zero function / Auto-span function
Functions
Response time selector function / Preset metal characteristic memory function
Cable length selector function / Interference suppression function
Temperature
Sensor head
0.03% of F.S./°C
1.
fluctuation
Controller
0.04% of F.S./°C
Power supply voltage
12 to 24 VDC ±10%, Ripple (P-P): 10% max.
Current consumption
220 mA max.
Sensor head
-20 to +105°C (-4 to 221°F), No freezing
Controller
0 to +50°C (32 to 122°F), No freezing
Relative humidity
35 to 85%, No condensation
Vibration
10 to 55 Hz, 1.5 mm double amplitude in X, Y and Z directions, 2 hours respectively
Enclosure rating
Sensor head: IP-67
Sensor head
Approx. 50 g
Approx. 50 g
Approx. 63 g
Approx. 80 g
Controller
Approx. 360 g
NPN open-collector: 100 mA (40 V) max.
Residual voltage: 1 V max. (N.C.)
The above data is obtained using an aluminum target (A5052 t = 1 mm). When measuring steel or stainless steel targets, refer to the characteristics of linearity for these
materials.
1. EX-008: When the distance between the sensor head and target is half the maximum measuring distance and the operating temperature is 10 to 40°C (50 to 104°F).
EX-016, 022: When the distance between the sensor head and target is half the maximum measuring distance and the operating temperature is 0 to 50°C (32 to 122°F).
Analog
output
Ambient
temperature
Model
Weight
Disconnection alarm output