Safety features

The two-hand control relay meets the following safety requirements:

}

The circuit is redundant with built-in self-monitoring

}

The safety function remains effective in the case of a component failure

}

The circuit prevents a further press stroke in the case of:

– Relay failure
– Contact welding
– Coil defect on a relay
– Open circuit
– Short circuit

}

The unit has an electronic fuse.

Block diagram/terminal configuration

Input

Input

A1 A2

S21 S22

=

Power

Feed-

back

(Reset)

S34

S11 S12

=

Y32

(~)

K1

K2

13 23 33

24 34

14

41

42

Interface expansion

unit

( )

*

*

Centre: Front view with cover, right: Front view without cover

Grey highlighted area: Applies only with U

B

= 48 – 240 V AC/DC

*Insulation between the non-marked area and the relay contacts: Basic insulation (overvolt-
age category III), safe separation (overvoltage category II)

Function description

}

The two-hand control relay must be activated by simultaneously pressing two buttons

within

0,5 s . If one or both of the buttons are released, the unit interrupts the control

command for the hazardous movement.

}

Reactivation: The output relays will not re-energise until both operator elements have

been released and then re-operated simultaneously.