20

PSEN cs4.1 M12/8-0.15m

12

M

18

48

.5

31

16

10

R8

8

19

26,4

4,

5

22

37

14,4

4,

5

22

37

18

14,4

18

Technical details

PSEN cs4.1a and PSEN cs4.1b

General

541111

541112

Approvals

CE, GOST, TÜV, cULus Listed

CE, GOST, TÜV, cULus Listed

Sensor's mode of operation

Transponder

Transponder

Electrical data

541111

541112

Supply voltage

Voltage

24 V

24 V

Type

DC

DC

Voltage tolerance

-20 %/+20 %

-20 %/+20 %

Output of external power supply

(DC)

1,0 W

1,0 W

Max. switching frequency

3 Hz

3 Hz

Switching current per output

100 mA

100 mA

Breaking capacity per output

2,4 W

2,4 W