Connection to pnozmulti, Connection to pss, Teaching in the actuator – Pilz PSEN cs4.1a User Manual
Page 13
PSEN cs4.1a/b/p/M12
Operating Manual PSEN cs4.1a/b/p/M12
22187-EN-02
13
Connection to PNOZmulti
Safety gate with switch type 3
I0, I1: Inputs OSSD
I2: Signal input
I2
I0
I1
grün
grau
gelb
Connection to PSS
Safety gate standard block SB64
I00, I01: OSSD inputs
I02: Signal input
grün
grau
gelb
Teaching in the actuator
Teaching in the actuator for the first time:
The first actuator detected by the safety switch (PSEN cs4.1) is automatically taught in as
soon as it is brought into the response range.
To teach in a new actuator:
}
The actuator that is to be taught in must be brought into the safety switch's response
range as the only transponder. As soon as the actuator is detected, the "Safety Gate"
LED will flash yellow.
}
After 20 s has elapsed, the "Safety Gate" LED turns to quick yellow flashes. Trigger a
system reset in the next 120 s by interrupting the power supply.
}
When the supply voltage is switched back on, the learning procedure is complete and
the number of permitted additional learning procedures is reduced by 1.
}
A maximum of 8 learning procedures are possible.
NOTICE
– The actuator must not be removed during the learning procedure.
– This actuator cannot be retaught on the same safety switch.