beautypg.com

Connection to pnozmulti, Connection to pss, Teaching in the actuator – Pilz PSEN cs4.1a User Manual

Page 13

background image

PSEN cs4.1a/b/p/M12

Operating Manual PSEN cs4.1a/b/p/M12
22187-EN-02

13

Connection to PNOZmulti

Safety gate with switch type 3

I0, I1: Inputs OSSD

I2: Signal input

I2

I0

I1

grün

grau

gelb

Connection to PSS

Safety gate standard block SB64

I00, I01: OSSD inputs

I02: Signal input

grün

grau

gelb

Teaching in the actuator

Teaching in the actuator for the first time:
The first actuator detected by the safety switch (PSEN cs4.1) is automatically taught in as
soon as it is brought into the response range.

To teach in a new actuator:

}

The actuator that is to be taught in must be brought into the safety switch's response

range as the only transponder. As soon as the actuator is detected, the "Safety Gate"
LED will flash yellow.

}

After 20 s has elapsed, the "Safety Gate" LED turns to quick yellow flashes. Trigger a

system reset in the next 120 s by interrupting the power supply.

}

When the supply voltage is switched back on, the learning procedure is complete and

the number of permitted additional learning procedures is reduced by 1.

}

A maximum of 8 learning procedures are possible.

NOTICE

– The actuator must not be removed during the learning procedure.
– This actuator cannot be retaught on the same safety switch.

This manual is related to the following products: