beautypg.com

Vintage Cellars Wine Guardian Split System Manual User Manual

Page 51

background image

46

Settings – Press and hold the “Mode” button for five (5) seconds to access the following

settings.

Deg F or Deg C




Setting 1

Press the “Down” arrow to change
temperature from Deg F to Deg C.

Press the “Up” arrow to change temperature
from Deg C to Deg F

.

Low temperature
alarm set point




Setting 2

Press “Mode” button to advance to Setting 2.

Press the “Up” or “Down” arrow buttons to
adjust to the desired set point. Factory default
is 50 Deg. F.

High temperature
alarm set point



Setting 3

Press “Mode” button to advance to Setting 3.

Press the “Up” or “Down” arrow buttons to
adjust to the desired set point. Factory default
is 65 Deg F.


Low humidity alarm
set point



Setting 4

Press “Mode” button to advance to Setting 4.

Press the “Up” or “Down” arrow buttons to
adjust to the desired set point. Factory default
is 5%.



High humidity alarm
set point



Setting 5

Press “Mode” button to advance to Setting 5.

Press the up or down arrow buttons to adjust

to the desired set point. Factory default is
95%.



Add or remove
humidifier






Setting 6

Press “Mode” button to advance to Setting 6.

Press the up or down arrow buttons to adjust

to the desired set point. Factory default is zero
(0).

Zero (0) = No humidifier
One (1) = Stand-alone remote mounted
humidifier
Two (2) = Integral Wine Guardian mounted
humidifier

Fan AUTO or ON



Setting 7

Press “Mode” button to advance to Setting 7.

Press the “Up” or “Down” arrow buttons to
adjust number to the desired set point. Factory
default is zero (0).

Zero (0) = Auto – fan only turns on when
there is a call for cooling or heating
One (1) = Fan On – fan remains on
continuously