Troubleshooting guide – Vintage Cellars Mini Ceiling Mount User Manual

Page 43

background image

www.whisperkool.com | Page 41

TROUBLESHOOTING GUIDE

Solution

Evaporator unit should be level in ceiling to prevent
leaking.
Check drain line to make sure water can flow freely.
Disconnect drain and clear out, check drain for blockage.

Fix drain line so there is a downward slope from the unit to the drain.

Melt ice with blow drier. Soak up with a towel.

Solution

Make sure fan is unobstructed; evaporator coil, and
condenser coil are clean and free of debris.
Call Customer Service at 1-800-343-9463
Shut system off for 1 hour to allow compressor to cool. Turn

back on and check for cooler airflow out. If compressor

runs, check for and clean condenser coil as possible cause

of compressor overheating. If problem repeats, contact

your installing technician to assist with troubleshooting.

Solution

1) If the system is maintaining the correct cellar

temperature and there is a dripping snowflake symbol

illuminated on the control, the system is going through

an anti-frost cycle. No action Required. 2) If the system is

not maintaining the correct cellar temperature, this may

be caused by a dirty evaporator coil. 3) Call installing

technician to troubleshoot, as the system may be low on

charge or an adjustment to the TXV.
Please contact the installing technician to troubleshoot.
Allow cooling system to revert back to cooling mode.
Shut system off for 1 hour to allow compressor to cool. Turn

back on and check for cooler airflow out. If compressor

runs, check for and clean condenser coil as possible cause

of compressor overheating. If problem repeats, contact

your installing technician to assist with troubleshooting.

Solution

Please contact the installing technician to troubleshoot.
Please contact the installing technician to troubleshoot.

Solution

Move bottle probe to a more central location.
Please contact the installing technician to troubleshoot.
Please contact the installing technician to troubleshoot.
Please contact the installing technician to troubleshoot.

Solution

Raise the Fon setting to increase the humidity level.

Unit leaks water

Possible Cause

Evaporator unit is not level.


Drain line clogged or kinked.

Drain is clogged preventing water form escaping.

Drain line does not have a downward slope.

Coil is iced causing drain pan ice and water overflowing.

Unit runs but does not cool

Possible Cause

Lack of air flow.


System undersized.

Compressor is overheating.

Evaporator fan runs but compressor does not

Possible Cause

Running an anti-frost cycle.

Compressor and/or starting components faulty.

System may be performing the WHM function.

Compressor may have overheated.

Compressor runs but evaporator fan does not

Possible Cause

Faulty fan motor.

Faulty controller.

Compressor short cycles

Possible Cause

Evaporator blows on bottle probe.

System low on refrigerant charge.

Condensing fan motor/capacitor faulty.

Compressor and/or starting components faulty.

Humidity in cellar too low

Possible Cause

Not enough moisture.