0 920i® electronic weigh center, 1 configuration, 0 920i – Rice Lake TradeRoute HL Series - Installation and Service Manual (Legal-for-Trade) User Manual
Page 28: Electronic weigh center

24
Trade
Route Installation Manual
3.0
920i
®
Electronic Weigh Center
Important
Configuration and calibration should be performed only by a Rice Lake distributor for Legal for Trade
sealing.
3.1
Configuration
The 920i indicator (integral in the electronic weigh center) is set up with all required parameters when it is shipped
with
Trade
Route
system. To interact with installed hardware the common parameters requiring configuration to all
Trade
Route
systems are shown in Table 3-3. The appropriate parameter values for popular net capacities are listed
in Table 3-4 and Table 3-5. Double check that the parameters are set appropriately for your system.
SCALES
SERIAL
FEATURE
SCALE x
GRADS
10000
number
See
FORMAT
Submenu
CONFIG
FORMAT
SPLIT
3INTVL
3RNG
2RNG
2INTVL
OFF
Specify for
SPLIT = OFF
....
....
....
....
Configuration of the
displayed capacity and
resolution is required.
Note
For a more detailed summary and instructions of configuration, see the 920i Installation Manual (PN 67887).
Figure 3-1. Scales Menu
Table 3-1. Scales Menu
SCALES Menu
Parameter
Choices
Description
Level 2 submenus
SCALEx
Allows configuration and calibration of each scale.
CONFIG
Lists available and associated A/Ds.
Level 3 submenus
GRADS
10000
1–9999999
Specifies the number of full-scale graduations if SPLIT=OFF. (For multi-range and
multi-interval scales [SPLIT
OFF], the GRADS value is derived from the capacity and
display divisions specified for the range or interval.)
The value entered must be in the range 1–9999999 and should be consistent with legal
requirements and environmental limits on system resolution.
To calculate GRADS, use the formula: GRADS = Capacity / Display Divisions.
Display divisions are specified under the FORMAT submenu.
SPLIT
OFF
2RNG
3RNG
2INTVL
3INTVL
Specifies whether the scale is full-range (OFF), multi-range (2RNG, 3RNG), or multi-interval
(2INTVL, 3INTVL). See 920i Manual for further descriptions.
FORMAT
PRIMAR
SECNDR
For standard scales (SPLIT=OFF), see submenu descriptions in Table 3-2. Also see 920i
Manual for further descriptions.