Rice Lake Digital/Diagnostic - iQube User Manual
Page 47

44
iQUBE
Installation Manual
Command
Description
DON.b#s
Set digital output on (active) at bit b (9–24), for
iQUBE
connected to slot s. NOTE: Odd numbered ports
use bits 9–16; even numbered ports use bits 17–24.
Example: To turn on digital output bit 1 for an
iQUBE
attached to port 3 (slot 0), use DON.9#0.
DOFF.b#s
Set digital output off (inactive) at bit b (9–24), for
iQUBE
connected to slot s. NOTE: Odd numbered ports
use bits 9–16; even numbered ports use bits 17–24.
Example: To turn off digital output bit 6 for an
iQUBE
attached to port 8 (slot2), use DOFF.22#2.
SJ.DIO.ALIAS.b#n
Digital I/O alias
SJ.DIO.b#n
Digital input function. See the
920i
Installation Manual, PN 67887, for more information
For SJ.DIO commands, digital inputs are specified by bit number (b, 1–8) and the number of the
920i
serial port to which the
iQUBE
is attached (n).
Table 8-6. DIG I/O Serial Commands
Command
Description
Values
SJ.ALG.SOURCE#n
Analog output source
OFF, system_name
SJ.ALG.FULLSC#n
Analog output full scale
0.000001–9999999.0
For commands ending with “#n”, n is the number of the
920i
serial port to which the
iQUBE
is attached
Table 8-7. ALGOUT Serial Commands (Valid Only If Analog Output Option Is Installed)
Command
Description
Values
CONTACT.COMPANY
Contact company name
company_name (up to 30 characters)
CONTACT.ADDR1
CONTACT.ADDR2
CONTACT.ADDR3
Contact company address
company_address (up to 30 characters for each line)
CONTACT.NAME1
CONTACT.NAME2
CONTACT.NAME3
Contact names
contact_names (up to 20 characters each)
CONTACT.PHONE1
CONTACT.PHONE2
CONTACT.PHONE3
Contact phone numbers
contact_phone_numbers (up to 20 characters each)
CONTACT.EMAIL
Contact e-mail address
contact_e-mail_address (up to 30 characters)
See Section 7.0 on page 38 for information about e-mail
notification of
iQUBE
alert messages.
CONTACT.NEXTCAL
Next calibration date
calibration_date
Table 8-8. Contact Serial Commands
Command
Description
Values
ALERT.FMT
Alert format
See Section 7.2 on page 39 for information about specifying
the alert format.
ALERT.SERV
Alert SMTP server address
0.0.0.0, SMTP_server_IP_address
ALERT.PRN
Alert printer port
PORTn
Table 8-9. Alert Serial Commands