Rice Lake Digital/Diagnostic - iQube User Manual
Page 46

920i Serial Commands
43
Command
Description
Values
SJ.SYS.NAME.s#n
System name
System1, system_name (24 characters, maximum)
SJ.SYS.PLATS.s#n
System platforms
0,0,0,0 (specify platform numbers, 1–4, assigned to sytem)
or NONE (to clear platform list)
For system (SJ.SYS.) commands ending with “s#n”, s is the system number, n is the
920i
serial port number.
Table 8-4.
920i iQUBE System Serial Commands
Command
Description
Values
SJ.DIAG.ZEROREF#n
Zero reference diagnostic enable
ON, OFF
SJ.DIAG.ZR.THRH#n
Zero reference threshold
0.0–9.999999
SJ.DIAG.ZR.%THRH#n
Zero reference percent threshold
0–100
SJ.DIAG.ZR.DELAY#n
Zero reference delay
0–65535
SJ.DIAG.CELLBAL#n
Cell balance diagnostic enable
ON, OFF
SJ.DIAG.CB.THRH#n
Cell balance threshold
0.0–9.999999
SJ.DIAG.CB.%TOLR#n
Cell balance percent tolerance
0–100
SJ.DIAG.CB.LOAD#n
Cell balance load
0.0–9999999.0
SJ.DIAG.LDRIFT#n
Load cell drift diagnostic enable
ON, OFF
SJ.DIAG.LD.LIMIT#n
Load cell drift limit
0.0–9.999999
SJ.DIAG.LD.%LIMIT#n
Load cell drift percent limit
0–100
SJ.DIAG.LD.TIME#n
Load cell drift time
0–65535
SJ.DIAG.LD.LOAD#n
Load cell drift load
0.0–9999999.0
SJ.DIAG.PKTOPK#n
Peak-to-peak diagnostic enable
ON, OFF
SJ.DIAG.PK.LIMIT#n
Peak-to-peak limit
0.0–9.999999
SJ.DIAG.CELLEMU#n
Cell emulation enable
ON, OFF
SJ.DIAG.CE.TYPE#n
Cell emulation type
AUTO1, AUTO2, MANUAL1, MANUAL2
SJ.DIAG.MOTBAND#n
Motion band
0.0–9999999.0
For commands ending with “#n”, n is the number of the
920i
serial port to which the
iQUBE
is attached.
Table 8-5.
920i iQUBE Diagnostic Serial Commands