68
Counterpart Counting Scale Indicator
5.8
Parts Reduction Counts
Parts reduction can also be done by using the minus key while the scale is in the weighing mode and the memory
annunciator is on.
1. Conduct a sampling process to determine the unit weight of the pieces, or key in a known weight or recall
an ID.
2. Enter known tare weight, or place an empty container on the scale to perform tare function. If ID was
recalled in step one, its tare value is already loaded.
3. Place the container (full of parts) on the scale. The number of pieces in the container is shown in the
PCS
area of the display.
4. Press the
Total +
softkey to store the number of pieces in the container. The memory (
M
) icon is shown. The
net weight of the items in the container is stored and the totalization count is incremented. The total piece
count value is shown in place of the piece weight value and will be labeled
ttl.
The total net weight is
shown in place of the normal ID Code: line - it is labeled as Total Weight.
5. Remove the number of parts required from the container and press the
Total -
softkey. The total piece count
value is now equal to the number of pieces removed. The number of pieces remaining in the container is
shown in the
PCS
area of the display. The total weight is now equal to the weight of the removed pieces.
6. Repeat step 5 as needed.
Once part reduction has been started, Pressing Total + will give you an error message.
5.9
Accumulate Feature For Weight
The accumulate feature allows a weight value to be accumulated. The following steps to use this feature.
1. Enable the Accumulate in the Scale Menu. Press the
On
key, and the display will say
Accumulator Enabled.
2. Set up the
Display Accum
—
(DSP ACC)
and
Swap Display (SWAPDSP)
softkey. See Section 1.7 on page 5 of
the manual for help on setting up softkeys.
3. The weight must be active on the display.
4. Each time there is a print, the weight value is added to the accum register and keeps track of how many
accums were completed. Product must be removed from the platform and the display returned to zero each
time this is done.
5.9.1
Printing the Accumulated Total
Press the
key to print the accumulated total when the Accum Value is displayed.
5.9.2
Clearing the Accumulated Total
1. Push the
CLR
key when the display
Accum
has been pressed.
2.
PRESS CLEAR TO VERIFY
is displayed. Press
CLR
again to clear the accum value.
5.9.3
IN/OUT Softkeys
Use the following steps to set up IN and OUT softkeys.
1. Push IN to add the displayed count value to quantity on hand of a stored ID code.
2. Push OUT to removed the displayed count value to quantity on hand of a stored ID code.
Note