Rice Lake Counterpart Configurable Counting Indicator - Installation and Operation Manual V2.3 - Rev C User Manual
Page 60

54
Counterpart Counting Scale Indicator
Setpoint 1-6 sub-menu
GROSS
NET
PIECECNT
%REL
Value
Source
Trip
Bandval
Hyster
Preact
Preval
Preadj
Prestab
Pcount
Relnum
Batch
Pshaccm
Pshprint
Pshtare
Access
Digout
Sense
Display and edit the gross value
DELAY
Value
Source
Pshaccm
Pshprint
Pshtare
Access
Digout
Sense
COUNTER
Value
Access
Digout
Gross, Net, Peicecnt, %Rel, Delay and Counter sub-menus
VALUE
number
BANDVAL
number
HYSTER
number
Specifies a band around the setpoint value that must be exceeded before the setpoint, once
off, can trip on again.
PREVAL
number
PREADJ
0.500000
0-9999999
Preact adjustment factor. For setpoints with PREACT set to LEARN, specifies a decimal
representation of the percentage of error correction applied (0.05 = 50%, 1.0 - 100%) each
time a PREACT adjustment is made.
PRESTAB
0
0-65535
Preact stabilization time-out. For setpoints with PREACT set to LEARN, specifies the time, in
0.1-second intervals, to wait for standstill before adjusting the PREACT value. Setting this
parameter to a value greater than zero disables the learn process if standstill is not achieved in
the specified interval.
PCOUNT
1
0-65535
Preact learn interval. For setpoints with PREACT set to LEARN, specifies the number of
batches after which the preact value is recalculated. The default value, 1, recalculates the
preact value after every batch cycle.
RELNUM
1
2
3
4
5
6
For the percent relative setpoint, specifies the number of the relative setpoint. The target
weight for the %REL setpoint is determined as the percentage (specified on the VALUE
parameter of the %REL setpoint) of the target value of the relative setpoint.
Parameters
Choices
Description
Table 3-20. Setpoint Menu Parameters in Weigh Mode