1 locking and unlocking - s-xl scale base, 2 locking and unlocking - s-yc scale base, Locking and unlocking - s-xl scale base – Rice Lake Counterpart Configurable Counting Indicator - Installation and Operation Manual V2.3 - Rev C User Manual
Page 14

8
Counterpart Counting Scale Indicator
2.2
Scale Base Assembly (if purchasing the scale base separate from indicator)
Do not turn the scale upside down. Always work with the scale on its side. Damage to the load cell can
occur if the scale is turned upside down.
Set up the scale on a stable, level surface.
2.2.1
Locking and Unlocking - S-XL Scale Base
The Counterpart S-XL scale base is delivered in a locked position to prevent damage to the load cells during
shipment. The scale base uses either one setscrew for the single-platform scale or two setscrews for the dual-
platform scale. The setscrews are located on the bottom of the base and must be removed before the scale is put
into service. Use the following procedure to unlock the scale base.
1. Turn the scale on its side.
Figure 2-1. Location of Load Cell Setscrews for Single and Dual-Platform Scales (DIGI S-XL Scale Base shown)
2. Remove the load cell setscrew using a hex wrench for the dual platform setscrews or a Phillips head
screwdriver for the single platform scale.
3. Tape the setscrews to the bottom of the scale or store in a safe place for possible future use.
2.2.2
Locking and Unlocking - S-YC Scale Base
The Counterpart S-YCL scale base is delivered in a locked position to prevent damage to the load cells during
shipment. The scale base uses two setscrews. The setscrews are located on the bottom of the base and must be
removed before the scale is put into service. Use the following procedure to unlock the scale base for the S-YC
Model.
1. Turn the scale on its side.
Figure 2-2. Location of Load Cell Setscrew for the DIGI S-YC Scale Base
2. Remove the load cell setscrews using a hex wrench which is included.
3. Tape the setscrews to the bottom of the scale or store in a safe place for possible future use.
Important
Dual platform load cell
setscrews
Single platform load
cell setscrews
Setscrew location