9 regulatory mode functions, Where, The function of the front panel – Rice Lake Counterpart Configurable Counting Indicator - Installation and Operation Manual V2.3 - Rev C User Manual
Page 103

Appendix
97
Where:
Polarity Note that industrial serial scales (IND SC) do not require the To change or match formats, use the same path to change formats. 9.9 Regulatory Mode Functions The function of the front panel TARE and ZERO keys depends on the value specified for the REGULAT parameter on the FEATURE menu. Table 9-5 describes the function of these keys for the NTEP, CANADA, OIML, and TARE and ZERO key functions are configurable when the REGULAT mode is set to INDUST (see Table 9-6 on page 97). Table 9-6 lists the subparameters available when configuring a scale using INDUST mode. The table includes the REGULAT Parameter Value Weight on Scale Tare in System Front Panel Key Function TARE ZERO NTEP zero or negative no no action ZERO yes CLEAR TARE positive no TARE yes TARE CANADA zero or negative no no action ZERO yes CLEAR TARE positive no TARE yes no action OIML zero or negative (not to exceed -20dd) no no action ZERO yes CLEAR TARE ZERO and CLEAR TARE positive no TARE ZERO yes TARE ZERO and CLEAR TARE if weight is within ZRANGE. No action if weight is outside of ZRANGE NONE zero or negative no TARE ZERO yes CLEAR TARE positive no TARE yes CLEAR TARE Table 9-5. TARE and ZERO Key Functions for REGULAT Parameter Settings REGULAT / INDUST Parameter REGULAT Mode Parameter Name Text Prompt INDUST NTEP CANADA OIML NONE SNPSHOT Display or Scale weight source DISPLAY DISPLAY DISPLAY DISPLAY SCALE ZTARE Remove tare on ZERO NO NO NO YES NO KTARE Always allow keyed tare YES YES NO YES YES MTARE Multiple tare action REPLACE REPLACE NOTHING REPLACE REMOVE NTARE Allow negative tare NO NO NO NO YES Table 9-6. REGULAT / INDUST Mode Parameters, Comparison with Effective Values of Other Modes
Units Status identifiers. However, the units
and number of decimal places must be specified. Units can be selected from the FORMAT menu; decimal places
should be indicated with a w-spec identifier. For example, a seven-digit weight reading requiring two decimal
places should be specified as
NONE regulatory modes.
default values of the INDUST subparameters and the effective (not configurable) values used by the NTEP,
CANADA, OIML, and NONE regulatory modes.