3 front panel configuration, 2 menu structures and parameter descriptions, Front panel configuration – Rice Lake 920i Installation Manual V2.0 User Manual
Page 25: Vided in section 3.2, Section 3.1.3
Configuration
21
3.1.3
Front Panel Configuration
Use the CONFIG submenu under the SCALES menu
to conÞgure A/D scales. For example, in an indicator
with a single-channel A/D card installed in Slot 1, the
Scale ConÞguration display will show the A/D listed
(
Slot 1 Channel 1
) under the
AVAILABLE A/D’s
column.
Use the
left
navigation key to select the A/D, then
press the center softkey,
Add
. The A/D is then moved
to the Associated A/DÕs column. If no other A/DÕs are
listed in the
AVAILABLE A/D’s
column, the center
softkey changes to
Done
, as shown in Figure 3-2.
Press
Done
to exit the Scale ConÞguration display.
See Section 10.4 on page 97 for information about
conÞguring serial scales.
Figure 3-2. Scale ConÞguration Display
The
920i
indicator can be conÞgured using a series of menus accessed through the indicator front panel when the
indicator is in setup mode. Table 3-1 summarizes the functions of each of the main menus.
3.2
Menu Structures and Parameter Descriptions
The following sections provide graphic representations of the
920i
menu structures and tables describing the
menu parameters. Default values are shown in bold type; numeric ranges and string values are shown in italic
type. Parameters shown surrounded by a dotted-line box only appear under the special circumstances explained
under each box.
Figure 3-3. ConÞguration Menu Flow
Menu
Menu Function
SCALES
Configuration
Configure and calibrate scales.
SERIAL
Serial
Configure communications ports.
FEATURE
Feature
Set date and time formats, truck mode, passwords, keyboard locks, regulatory mode, and
initial consecutive number value, define softkeys and setpoint prompts.
PFORMT
Print Format
Set print format used for header, gross, net, truck in/out, setpoint, and auxiliary ticket formats.
See Section 6.0 on page 53 for more information.
SETPTS
Setpoints
Configure setpoints and batching mode.
DIG I/O
Digital I/O
Assign digital input/output functions.
ALGOUT
Analog Output
Configure analog output module. Used only if analog output option is installed.
VERSION
Version
Display installed software version number. The Reset Config softkey on the Version menu can
be used to restore all configuration parameters to their default values.
Table 3-1.
920i Menu Summary
SCALES
SERIAL
FEATURE
PFORMT
SETPTS
DIG I/O
ALGOUT
VERS
Shown only if
Analog Ouptut
card is installed