0 appendix, 1 error messages, 2 continuous output (stream) format – Rice Lake SURVIVOR LV Series Livestock Ring Scale User Manual
Page 43: Appendix
![background image](/manuals/639095/43/background.png)
Appendix
39
8.0
Appendix
8.1
Error Messages
The 590 AG Indicator provides a number of front panel error messages to assist in problem diagnosis. Table 8-1
lists these messages and their meanings.
Table 8-1. 590 AG Indicator Error Messages
Error Message
Description
Solution
ADCERR
A/D not responding
Call Rice Lake Weighing Systems (RLWS) Service.
ADCKSM
A/D coefficient checksum error
CFCKSM
Configuration checksum error
Use TEST menu to perform DEFLT (restore defaults) procedure, then
recalibrate load cells.
DSPERR
Display error
Call RLWS Service.
EEPERR
EEPROM write error
LCCKSM
Load cell calibration checksum error
Recalibrate load cells.
LCPERR
Load cell power failed
Replace batteries. If error still shown, call RLWS Service.
OVERFL
Overflow error
Weight value too large (> 999999) to be displayed. Check
configuration.
PFCKSM
Print format checksum error
Check print formats for errors.
RAMERR
RAM test failed
Call RLWS Service.
TARERR
EEPROM read error
Use TEST menu to perform DEFLT (restore defaults) procedure, then
recalibrate load cells.
VIREE
EEPROM error
Use TEST menu to perform DEFLT (restore defaults) procedure, then
recalibrate load cells and reconfigure indicator.
------
Overrange error
Gross value exceeds overload limit. Check configuration.
______
A/D underrange
Weight value too small (< –99999) to be displayed or A/D reading <
–2.5 mV. Check load cell input signal.
STNDBY
Standby mode
Press any key to return to operating mode.
8.2
Continuous Output (Stream) Format
Figure 8-1 shows the continuous output format sent to the 590 AG Indicator serial port when the STREAM
parameter (SERIAL menu) is set to either LFT or INDUST.
ASCII 02
decimal
Polarity:
<space> = Positive
<–> = Negative
Weight: 7 digits, right-justified, dummy
zeroes, decimal point with no leading
zeroes except for leading zero immediately
preceding the decimal point. Leading
zeroes transmitted as spaces.
L = pounds
K = kilograms
T = tons
G = grains
<space> = grams
O = ounces
G = Gross
N = Net
Status:
<space> = valid
I = Invalid
M = Motion
O = Over/under range
or
Figure 8-1. Continuous Output Data Format