beautypg.com

3 calibration menu, Calibration menu – Rice Lake SURVIVOR LV Series Livestock Ring Scale User Manual

Page 26

background image

22

590 AG Indicator Operators Manual

3.2.3

Calibration Menu

See Section 4.0 for calibration procedures.

XXXXXXX

XXXXXXX

WZERO

*CAL*

Display and edit

zero calibration

A/D count value

Display and edit

test weight value

WVAL

*CAL*

Display and edit

span calibration
A/D count value

WSPAN

VERS

PROGRM

PFORMT

SERIAL

CALIBR

CONFIG

FORMAT

Press Enter to

remove offset from

zero and span

calibrations

REZERO

*CAL*

Figure 3-6. Calibration Menu

Table 3-2. Calibration Menu Parameters

CALIBR Menu

Parameter

Choices

Description

WZERO

Calibrate zero, display and edit the zero calibration A/D count value.

WVAL

Display and edit the test weight value.

WSPAN

Calibrate span, display and edit the span calibration A/D count value.

REZERO

Press Enter to remove an offset value from the zero and span calibrations.
Use this parameter only after WZERO and WSPAN have been set. See Section 4.1 for more
information about using this parameter.