beautypg.com

7 analog output, 4 analog output module installation, 5 enclosure reassembly – Rice Lake 420 Plus HMI Digital Weight Indicator Installation Manual User Manual

Page 15: 6 board removal, Analog output

background image

420 Plus Installation Manual - Installation

11

2.3.7

Analog Output

If the optional analog output module is installed, attach

the output cable to connector J1 on the analog output

bo ard . Ta ble 2 - 5 lists the analog output pin

assignments.
Use the ALGOUT menu to configure and calibrate the

analog output module when cabling is complete. See

Section 2.4 for information about installing the analog

output module.

Table 2-5. Analog Output Module Pin Assignments

Pin

Signal

1

+ Current Out

2

– Current Out

3

+ Voltage Out

4

– Voltage Out

2.4

Analog Output Module Installation

To install or replace the analog output module (PN

85659), follow the steps listed in Section 2.2 on page 6

for opening the

420 Plus

enclosure.

Mount the analog output module on its standoffs in the

location shown in Figure 2-4 8 and plug the module

input into connector J9 on the

420 Plus

board. Connect

output cable to the analog output module as shown in

Table 2-5, then reassemble the enclosure (Section 2.5).
See Figure 7.8 50 for analog output calibration

procedures.

2.5

Enclosure Reassembly

Once cabling is complete, position the backplate over

the enclosure and reinstall the backplate screws. Use

the torque pattern shown in Figure 2-6 to prevent

distorting the backplate gasket. Torque screws to 15

in-lb (1.7 N-m).

1

6

9

4

2

5

7

10

Torque Pattern

8

3

Figure 2-6. 420 Plus Enclosure Backplate

Torqued screws may become less tight as the gasket is

compressed during torque pattern, therefore a second

torque is required using the same pattern and torque

value.

NTEP - Approval
Fastener

Figure 2-7. NTEP Sealing

2.6

Board Removal

If you must remove the

420 Plus

CPU board, use the

following procedure:

1. Disconnect power to the indicator. Remove

backplate as described in Section 2.2 on

page 6.

2. Disconnect power supply cable from connector

J7 on the

420 Plus

CPU board.

3. Unplug connectors J1 (load cell cable), J2

(digital inputs), J3 (EDP/RS-232), J4 (serial

communications), J6 (digital outputs), and J10

& J11 (keypad ribbon cables). If an analog

output board is installed, disconnect the analog

output cable. See Figure 2-4 8 for connector

locations.

4. Remove the five screws from the CPU board,

then lift the board out of the enclosure.

To replace the CPU board, reverse the above

procedure. Be sure to reinstall cable ties to secure all

cables inside the indicator enclosure.