Head-sill-reinforcing – Oldcastle BuildingEnvelope ICR-225 User Manual
Page 33

30
March 2012
Phone: 1-866-OLDCASTLE (653-2278)
Web Address: www.oldcastlebe.com
I C R - 2 2 5 - I N S T A L L A T I O N M A N U A L
Figure 32
Head anchor (Do Not
pre-install onto
building)
Install 6” reinforcing sleeve
prior to attaching Mullion
sleeve located at Head anchor
(see Detail A for location)
Access holes
Vertical attachment
screw beyond
Vertical Mullion
Vertical attachment screw.
Fasten through reinforcing
sleeve
Install 8” reinforcing sleeve
prior to attaching Mullions.
Sleeve located at Vertical
Mullion connections. (See
Detail “A” for location)
Head and Sill Reinforcing Sleeves (6” System)
Refer to approved
shop drawings
Head anchor
Head reinforcing
sleeve
Refer to approved
shop drawings
Seal reinforcing
sleeve