Weep-holes-typeb – Oldcastle BuildingEnvelope ICR-225 User Manual
Page 21

18
March 2012
Phone: 1-866-OLDCASTLE (653-2278)
Web Address: www.oldcastlebe.com
I C R - 2 2 5 - I N S T A L L A T I O N M A N U A L
FRAME FABRICATION TYPE “B”
Weep Holes
Figure 18
HP-1004
Baffle
SPW-295
Horizontal
Head
5/16” Dia. Weep Hole @ 1/4 points
of ea. Lite; (Typical at Horiz. and
Sill and incidental Water Head)
NOTE: Weep
required at Head
for incidental
water only!
Baffle Retainer
ICW-12 Clip typical
ICR- 312 Baffle Clip @
incidental Water Head
Sill
ICR- 312 Baffle
Clip @ Weeps
5.4 Install ICW-12 Isolator Clips on all vertical and horizontal framing members at 12” o.c. Stagger the clips by
approximately 2” at ends and 6” at intermediate clips.
See Figure 18 . ICR-312 isolator clips/baffles must be
installed over each weep hole at the head or horizontals. Once clips are installed, snap face caps into position.
The vertical caps should be installed first, then horizontal, head and sill caps.