Frame-sealing-typeb – Oldcastle BuildingEnvelope ICR-225 User Manual
Page 22

19
March 2012
Phone: 1-866-OLDCASTLE (653-2278)
Web Address: www.oldcastlebe.com
I C R - 2 2 5 - I N S T A L L A T I O N M A N U A L
Figure 19
Type "B" Frame Seals
Stagger Clips as shown at
Head and Sill members
Apply sealant to top of
Jamb at inside and exterior
surfaces as shown
ICW-12 Clips (Typical)
ICW-312 Clip at weeps
for incidental water
head installations
NOTE: Additional sealant may be
required along face of vertical to Head
and Horizontal connections. Tool
sealant at these locations to insure
proper seals.
Apply
sealant to
top of SSG
Mullion
Apply sealant to Mullion
along interior and exterior
surfaces of Mullion as shown
ICW-12 (Typical)
ICW-312 at weeps
Apply sealant along face of Mullion and
Shear Block prior to installing Horizontal
Apply sealant at inside and outside
surfaces of Sill at captured
Mullions and Jambs
ICW-12 Clips @
12” O.C. stagger
as shown
Apply sealant
as shown at
SSG Mullion
Apply sealant at
Jambs as shown
FRAME SEALING TYPE “B”
5.5 Seal ends of vertical and horizontal framing members before assembly. See Figure 19.