 Remove the 14 screws securing the KPA500 top cover as shown below. Do not remove the screw

indicated. It is part of the safety interlock switch mechanism. Lift the top cover off.

 Three taps are provided via red, green and yellow wires. Choose the tap according to the actual

mains voltage at the outlet you plan to use for the KPA500. If you cannot measure your mains
voltage, use the yellow tap.

115V Nominal Mains

TAP

230V Nominal Mains

95V to 105V

GREEN

190V to 210V

106V to 115V

RED

211V to 230V

116V to 125V

YELLOW

231V to 250V

 Be sure to place the unused taps side-by-side on the terminals at the back panel as shown. Do not

leave them floating loose inside the unit.

 Replace the top cover before proceeding. An interlock switch prevents operating the amplifier with

the top cover removed.