beautypg.com

Operation, Power on – Elecraft KPA500 Owner's Manual User Manual

Page 15

background image

15

Operation

Power On

1. Ensure a suitable 50 ohm load is attached to the

RF OUTPUT

connector on the rear panel (Figure

1,

). A dummy load is recommended for initial tests.

2. Enable the power supply by pressing the rear panel rocker switch (Figure 1,

) to the On (I)

position.

Switches with a legend above and below the pushbutton have two

functions. Tap (press briefly) to activate the function labeled above a switch.
Hold
to activate the function labeled below the switch. In the text, tap
functions are shown like this:

T E M P

. An example of a hold function is

P K

H O L D

.

Figure 5. KPA500 Front Panel.

3. Tap the

O N

switch

. The LCD

and

STBY

LED should light. When you tap the

O N

switch again to

turn the amplifier off you will hear the fan run. This is done to bleed off the 60V power supply voltage.
The fan stops when the voltage reaches a safe level so, if you are preparing to open the KPA500 cabinet
for any reason, be sure to allow the fan to run until it stops before switching off power with the rear
panel rocker switch or unplugging the KPA500 from mains power.

If at any time the

FAULT

LED

lights, refer to Fault Conditions, pg. 18.