beautypg.com

Antiwalk block installation, Step #58 step #57, Interior gasket installation – EFCO 955 Series User Manual

Page 41: Step #56 antiwalk block installation

background image

Cut the drive-in wedge gasket (W105) to the height and width D.L.O (+) 2%.
Install the vertical gasket first, then follow with the horizontal gasket.

Install the horizontal removable glass stops to the openings at the head and
intermediate horizontals. See detail #57 above.

STEP #58

STEP #57

LOCATE AT THE

MIDPOINT OF LITE

walk and insert into the deep pocket at midpoint. See the details below.

SECTION VII - GLASS INSTALLATION

Choose the appropriate antiwalk block for the required glass type. Use
block #HN50 at 1/4" glass and #HN53 at 1" glass. Compress the anti-

REQUIRED AT
DEEP POCKET

ONLY

INTERIOR GASKET INSTALLATION

ANTIWALK

BLOCK

ANTIWALK

BLOCK

#HN50 OR

#HN53

#8685 OR

#8652 STOP

STEP #56

ANTIWALK BLOCK INSTALLATION

PAGE #39

Detail #58

Detail #57

Detail #56

the middle of the loops until the gasket is installed.

Insert the ends of the gasket first, then set the middle and proceed to set

CONT.

JDA 9/2000