Weep baffles are cut from (1) HCW3, halved and then quartered. This provides
8) weep baffles per HCW3 to be used at the horizontal face. See Detail #11 below.

3/4"

HCW3

4"

Detail #11

1"

2"

STEP #10

1/2"

3/8"

1/4" at splice joints for expansion. Splice ONLY at center lines of vertical mullions.

3" long and trimmed to fit, for the face splice caulk backer.

Due to the expansion characteristics of the aluminum face member
and also to maintain the 1/4" splice joint, 15 feet is the recommended
cut length for the face member. Use #WM96 bond breaker tape,

{

NOTE:

HORIZONTAL FACE LENGTH (15 ft. max.)

1G59

8663

See Detail #10 below.

INTERIOR

D.L.O.

2 3/8"

Detail #10

K461 BRIDGE

8663

REQUIRED

2 3/8"

D.L.O.

D.L.O.

1/4"

8663

D.L.O.

2 3/8"

(CONT.)

Cut horizontal face member (#8553) to span 3 lites (or a maximum of 15’-0"). Allow

SECTION IV - FABRICATION

INTERMEDIATE HORIZONTAL FACE

STEP #9

PAGE #15

JDA 11/2000

1/4"

BOND BREAKER TAPE APPLIED

TO INSIDE OF FACE MEMBER

CENTERED ON GAP

GAP DETAIL EXAGGERATED