beautypg.com

EFCO 8800 Series Assembly Instructions Vol.3 User Manual

Page 6

background image

EFCO 2009

Page 6

Series 8700 / 8800 Unitized Curtain Wall Installation Instructions - Volume 3

4. Apply the mullion anchor assemblies to the unit

corner mullions (KV09 and KV10). Insert (3) bolts
(3/8”-16 x 4 1/2” HX-MS 18-8) through the
anchors and mullion.

5. Use right and left hand corner anchor assemblies

to orient the tops of the anchors and mullion as
shown and noted in Figures 3, 4 and the END
VIEW
, and insert the bolt through the anchors and
mullion.

6. Secure the anchors with (3) 3/8”-16 nylon insert

stop nuts (M172).

Section 7 - Outside 90° Corner Unit Frame Assembly : A. Mullion Subassembly

END VIEW

Top of

Mullion

Anchor
Assembly

M172

Unit Corner
Mullion

3/8”-16 x 4 1/2”

HX-MS 18-8

Unit Corner

Mullion

Top of

Mullion

Figure 4

Figure 3

Anchor Assembly

(KV10)

Anchor Assembly

(KV09)

Anchor Assembly

(KV10)

Anchor Assembly

(KV09)

This manual is related to the following products: