Series 8700 / 8800 Unitized Curtain Wall Installation Instructions - Volume 3
Section 10 - Inside 90° Corner Unit Glazing Preparation : SSG and Captured
Figure 71
Apply the WC18 spacer
gasket to the mullions.
1. Thoroughly clean all debris from the shadow box and back panel areas if the project has shadow boxes or back panels.
2.
Using an approved solvent or cleaner, clean the surfaces of the mullions to receive the WC18 spacer gasket and sealant of all oils and other
contaminants. The sealant manufacturer’s preparation and application instructions should be followed exactly.
3. If sealant primer is required, apply it per the primer/sealant manufacturer’s instructions. See Figures 72 - 76 on page 28 for more detail.
4. Refer to Volume 2, pages 6 and 7 of the S-8000 Unitized Curtain Wall Assembly Instructions for more information.