EFCO 8800 Series Assembly Instructions Vol.2 User Manual
Page 9
EFCO 2009
Page 9
Series 8700 / 8800 Unitized Curtain Wall Assembly Instructions - Volume 2
3. Set the glazing on the silicone spacer gaskets positioned as shown below. The edge of the glazing is flush with the edge of the vertical mullion. Refer to
Figure 9 below. Ensure the glazing is pressed firmly onto the setting blocks of the temporary retainers as shown in Figures 10 and 11.
4. Align the glazing as shown and noted. Ensure the glazing is positioned with the exterior side out, and the bottom of the glazing to the setting blocks. Care
should be exercised to avoid shifting or rolling the spacer gaskets when adjusting the position of the glass.
5. After the glass is aligned and in the final position, remove the setting blocks and temporary glazing locators.
6. Apply structural silicone sealant into the void between the glass and mullion per the sealant manufacturer’s application instructions. A 3/8” backer rod should
be applied into the isolator reglet to prevent sealant from getting into the reglet (see Figure 9). See additional notes, and Figures 12, 13, and 14 on page 10
for sealant application and tooling instructions.
7. Immediately tool the sealant joint after application to insure the joint is completely filled with sealant on all four sides of each piece of glazing. Make sure no
air bubbles or voids are present in the sealant joint.
8. Remove the backer rod, before the sealant begins to cure and skin over.
Section 5 - SSG Unit Glazing: B. Setting and Caulking Glazing
Figure 10
Figure 11
Figure 8
Set glazing onto the silicone
spacer gaskets and against
the setting blocks at the
temporary glazing locators.
Figure 9
Note:
Only silicone sealants
which have been
developed and tested
specifically for structural
glazing applications
should be used for
glazing purposes.
SILL
HEAD
JAMB
JAMB
Figure 10
Figure 9
Figure 11
Apply structural silicone
sealant into the void and
tool the joint to fill the
void completely.
Insert a 3/8” backer rod
into isolator reglet to keep
free of sealant. Remove the
backer rod immediately
before sealant begins to
skin over.
Glass is flush with
edge of mullion.
KV02