beautypg.com

EFCO 8800 Series Assembly Instructions Vol.2 User Manual

Page 8

background image

EFCO 2009

Page 8

Series 8700 / 8800 Unitized Curtain Wall Assembly Instructions - Volume 2

Section 5 - SSG Unit Glazing : A. Temporary Glazing Locators

Figure 6 - SSG Intermediate Horizontal

Figure 7 - SSG Stack Sill

1. In order to properly

locate the glazing,
temporary adapters must
be used at the bottom
edge of the glazing.
Apply two temporary
glazing locators (KV01,
KV02)
at approximate
quarter points at the sill
and intermediate
horizontal locations as
shown in Figures 5, 6,
and 7.

2. Using an approved

solvent or cleaner,
thoroughly clean the
edges of the glazing
that will contact the
structural silicone and
spacer of all oils and
other contaminants.

Once the glass has been
cleaned, it should be
handled with gloves to
avoid contaminating the
edges that come into
contact with the
structural silicone
glazing joint.

Figure 5

Temporary Glazing

Locators

HS32

L142

HS32

17B7

17H6

L142

KV02

KV01