EFCO 8800 Series Assembly Instructions Vol.2 User Manual
Page 8
EFCO 2009
Page 8
Series 8700 / 8800 Unitized Curtain Wall Assembly Instructions - Volume 2
Section 5 - SSG Unit Glazing : A. Temporary Glazing Locators
Figure 6 - SSG Intermediate Horizontal
Figure 7 - SSG Stack Sill
1. In order to properly
locate the glazing,
temporary adapters must
be used at the bottom
edge of the glazing.
Apply two temporary
glazing locators (KV01,
KV02) at approximate
quarter points at the sill
and intermediate
horizontal locations as
shown in Figures 5, 6,
and 7.
2. Using an approved
solvent or cleaner,
thoroughly clean the
edges of the glazing
that will contact the
structural silicone and
spacer of all oils and
other contaminants.
Once the glass has been
cleaned, it should be
handled with gloves to
avoid contaminating the
edges that come into
contact with the
structural silicone
glazing joint.
Figure 5
Temporary Glazing
Locators
HS32
L142
HS32
17B7
17H6
L142
KV02
KV01