EFCO 8800 Series Assembly Instructions Vol.2 User Manual
Page 20

EFCO 2009
Page 20
Series 8700 / 8800 Unitized Curtain Wall Assembly Instructions - Volume 2
Section 6 - Captured Unit Glazing : A. Temporary Glazing Locators
Figure 51 - Captured Intermediate Horizontal
Figure 52 - Captured Stack Sill
1. In order to properly
locate the glazing,
temporary adapters must
be used at the bottom
edge of the glazing.
Apply two temporary
glazing locators KV03
AND KV04 at
approximate quarter
points of the sill and
intermediate horizontal
locations as shown in
Figures 50, 51, and 52.
2. Using an approved
solvent or cleaner,
thoroughly clean the
edges of the glazing
that will contact the
structural silicone and
spacer of all oils and
other contaminants.
Once the glass has been
cleaned, it should be
handled with gloves to
avoid contaminating the
edges that come into
contact with the
structural silicone
glazing joint.
Figure 50
17B9
(2) HS31
L142
17B5
(2) HS31
L142
Temporary Glazing
Locators
KV03