Delayed egress operations, Green led, Cylinder mortise – Detex Delayed Egress With Magnetic Lock User Manual
Page 6: Lhr shown), Home key position, Pushpad red led siren
Green LED
push and hold deadlatch while
performing alarm test operations
ARMING AND AUTHORIZED EXIT
Insert key, turn CW to a stop. Green LED will blink twice to indicate the unit is disarmed, then BOTH
LED's will turn off.
With door closed, insert key in the cylinder, turn CCW then back to the home key position and remove it.
LED glows green. Authorized personnel can exit the door during this rearm cycle. After a 1, 5 or 15-second
arming period, alarm issues three quick beeps and LED goes off,indicating that the unit is armed.
DISARMING
For BENCH TESTING:
Deadlatch
Cylinder
Mortise
Turn Key CCW To Arm
Glowing Green LED
(LHR shown)
BLINK
BLINK
OFF
OFF
Armed - status ON
Disarmed - ON
Home Key
Position
DELAYED EGRESS OPERATIONS
PushPad
Red LED
Siren
EXITING UNDER ALARM
To exit, push and maintain pressure on the pushpad. LED flashes RED and alarm pulses on and off for 15
seconds. After 15 seconds, alarm issues short and long pulses to indicate that you can exit by depressing
the pushpad. Alarm sounds continuously and LED is steady RED. Turn key CW to stop alarm. In case of
fire, the fire alarm over-rides the 15 second delay and the door opens without delay when the pushpad is
pushed.
SIREN SOUNDS
THREE CHIRPS
SLOW PULSE
FAST PULSE
BATTERY BACKUP FOR ALARM
If battery voltage is low (7 volts or less), unit remains armed but LED flashes RED and unit beeps
twice every 45 seconds. Replace battery as soon as possible.
LOW BATTERY INDICATION
A 9-volt battery is included as a backup power source for the alarm siren if power is lost.
To disable low battery indication, slide "DisLoBat" switch to 'ON'. See EM ELECTRICAL OPTIONS page.
DOUBLE CHIRP
GREEN
RED
OFF
OFF
ON
ON
SLOW BLINKING
FAST BLINKING
DOUBLE BLINK
OFF
OFF
OFF
OFF
OFF
ON
ON
NORMAL OPERATION
LED COLOR
Factory installed jumper removed from terminals 3 & 4
Indicates the unit is in process of arming. The siren will chirp three times to indicate the unit is armed and
green LED will turn off
Pushpad is depressed, delay to open started
This indicates either armed or disarmed
Delay to open expired
Delay to open expired, door has been opened
Low Battery - every 45 seconds
ON
Red LED while alarming
FUNCTION
Turn Key CW To Disarm
104878 Page 6