background image

Green LED

push and hold deadlatch while

performing alarm test operations

ARMING AND AUTHORIZED EXIT

Insert key, turn CW to a stop. Green LED will blink twice to indicate the unit is disarmed, then BOTH

LED's will turn off.

With door closed, insert key in the cylinder, turn CCW then back to the home key position and remove it.

LED glows green. Authorized personnel can exit the door during this rearm cycle. After a 1, 5 or 15-second

arming period, alarm issues three quick beeps and LED goes off,indicating that the unit is armed.

DISARMING

For BENCH TESTING:

Deadlatch

Cylinder

Mortise

Turn Key CCW To Arm

Glowing Green LED

(LHR shown)

BLINK

BLINK

OFF

OFF

Armed - status ON

Disarmed - ON

Home Key

Position

DELAYED EGRESS OPERATIONS

PushPad

Red LED

Siren

EXITING UNDER ALARM

To exit, push and maintain pressure on the pushpad. LED flashes RED and alarm pulses on and off for 15

seconds. After 15 seconds, alarm issues short and long pulses to indicate that you can exit by depressing

the pushpad. Alarm sounds continuously and LED is steady RED. Turn key CW to stop alarm. In case of

fire, the fire alarm over-rides the 15 second delay and the door opens without delay when the pushpad is

pushed.

SIREN SOUNDS

THREE CHIRPS

SLOW PULSE

FAST PULSE

BATTERY BACKUP FOR ALARM

If battery voltage is low (7 volts or less), unit remains armed but LED flashes RED and unit beeps

twice every 45 seconds. Replace battery as soon as possible.

LOW BATTERY INDICATION

A 9-volt battery is included as a backup power source for the alarm siren if power is lost.

To disable low battery indication, slide "DisLoBat" switch to 'ON'. See EM ELECTRICAL OPTIONS page.

DOUBLE CHIRP

GREEN

RED

OFF

OFF

ON

ON

SLOW BLINKING

FAST BLINKING

DOUBLE BLINK

OFF

OFF

OFF

OFF

OFF

ON

ON

NORMAL OPERATION

LED COLOR

Factory installed jumper removed from terminals 3 & 4

Indicates the unit is in process of arming. The siren will chirp three times to indicate the unit is armed and

green LED will turn off

Pushpad is depressed, delay to open started

This indicates either armed or disarmed

Delay to open expired
Delay to open expired, door has been opened
Low Battery - every 45 seconds

ON

Red LED while alarming

FUNCTION

Turn Key CW To Disarm

104878 Page 6