Cabletron Systems Smart 04-0053-01 User Manual
Page 75

SmartSwitch ATM User Guide 5-9
Virtual Ports and Static Connections
Virtual Ports
Note
For PNNI, the number of VPIs used by each virtual port should be one (1). For
virtual UNI, the number of VPIs used by each virtual port should correspond to
the number of VPIs on the user side of the UNI connection (For information on
virtual UNI, refer to the ATM Forum specification for ILMI 4.0.).
The following is a practical, step-by-step example of creating a virtual port on physical port
7A1
that controls a single
VPI.
1.
Use the
set portconfig
command to turn signaling off on physical port
7a1
:
SmartSwitch # set portconfig
PortNumber() : 7a1
PortAdminStatus(up) :
IlmiAdminStatus(up) :
SigType(autoConfig) : nnipvc
— Turn off signaling by setting SigType to
nnipvc
SigRole(network) :
InterfaceType(private) :
MaxVpiBits(0) :
— Default MaxVpiBits = 0
MaxVciBits(13) :
— Default MaxVciBits = 13
MaxSvcVpci(0) :
MinSvcVci(32) :
MaxVccs(8192) :
MaxSvpVpci(0) :
MaxVpcs(0) :
SmartSwitch #
2.
Use the
set portconfig
command to assign two bits to
MaxVpiBits
.:
SmartSwitch # set portconfig
PortNumber() : 7a1
PortAdminStatus(up) :
IlmiAdminStatus(up) :
SigType(nniPvc) :
SigRole(network) :
InterfaceType(private) :
MaxVpiBits(0) : 1
— Set to 1 — this translates to VPIs = 2
1
-1 = 1
MaxVciBits(12) :
— Notice that MaxVciBits has reduced itself by 1 bit
MaxSvcVpci(7) :
MinSvcVci(32) :
MaxVccs(8192) :
MaxSvpVpci(7) :
MaxVpcs(7) :
SmartSwitch #
Note
The command
set portconfig
is used here twice for the purposes of clarity only.
Normally, you would turn off signaling and set the
MaxVpiBits
within the same
instance of
set portconfig
.