beautypg.com

3 troubleshooting pnni links, 1 switches in same peer group, 2 switches in different peer groups – Cabletron Systems Smart 04-0053-01 User Manual

Page 109: Switches in same peer group -3, Switches in different peer groups -3

background image

SmartSwitch ATM User Guide 9-3

Troubleshooting

Troubleshooting PNNI Links

-

Do devices begin to register with the LES and BUS once multi-point signaling is turned off?

7.

Check whether BUS is connected.

Use

show busclient

to check whether devices are registered with the BUS. If clients are registered,

check end node configuration. If not registered, check multi-point signaling.

Use

set leselan

to turn off multi-point signaling on a per-ELAN basis.

-

Do devices begin to register with the LES and BUS once multi-point signaling is turned off?

Check IISP routes to the switch containing the LES and BUS.

-

Are all IISP routes correct?

-

Does a new IISP route need to be added so devices can reach the LES and BUS?

8.

If working through these questions does not solve the problem, contact Cabletron Systems Customer
Service. (see Appendix B, "Technical Support").

9.3

TROUBLESHOOTING PNNI LINKS

You have physically connected another company’s ATM switch with your ATM SmartSwitch. Each switch supports
PNNI, but there is no connectivity between the two devices. When dealing with PNNI connectivity, two possible
configurations must be considered:

The ATM SmartSwitch and the other switch are in the same peer group

The ATM SmartSwitch and the other switch are is different peer groups

Use the following procedures to diagnose and resolve PNNI connectivity problems.

9.3.1

Switches in Same Peer Group

1.

Check the physical connection. Make sure that the switches are connected correctly.

2.

Check that both switches are in the same peer group. On the ATM SmartSwitch, enter the

show

pnninode

command to view the peer group ID. If not the same peer group, perform the following:

-

Set the peer group ID on either switch to match the other. On the ATM SmartSwitch, use the

set

pnnipeergroup

command to change the peer group ID.

3.

Check the signalling type of each switch. If either switch does not show PNNI as the signaling type
on the connecting port. Perform the following:

-

Turn off ILMI and manually set the signaling type to PNNI. On the ATM SmartSwitch, enter
the

show portconfig

command to view signaling type for all ports. If necessary, use the

set

portconfig

command to turn off ILMI and manually set signaling to

pnni10

.

4.

If none of the above actions have corrected the problem, contact Cabletron Systems Customer
Service (see Appendix B, "Technical Support").

9.3.2

Switches in Different Peer Groups

1.

Check the physical connection between the peer groups. Make sure that the switches are connected
correctly.