Cabletron Systems Smart 04-0053-01 User Manual
Page 38

2-20 SmartSwitch ATM User Guide
Creating an Emulated LAN
IP Over ATM and LANE
1.
On both SW1 and SW2, enter the
stop lecs
command to make sure each LECS is down
SW1 # stop lecs
Confirm(y/n)?:y
NOTICE - 'LECS' ***** LECS shutdown *****
SW1 #
2.
On both SW1 and SW2, enter the
stop les
command to stop each switch’s LES and BUS
SW1 # stop les
STOPPING LES/BUS
Confirm(y/n)?:y
NOTICE - 'ZLESSRV' ***** LES shutdown *****
SW1 #
3.
On both SW1 and SW2, enter the
set lnniinfo
command to assign a number to each switch’s
LECS. Make sure that each
LECSID
is unique.
SW1 # set lnniinfo
LECSID(-1) : 0
— On SW1, LECSID will be zero
SW1 #
Similarly, on SW2, enter the
set lnniinfo
command, specifying a different LECSID for SW2
SW2# set lnniinfo
LECSID(-1) : 1
— On SW2, LECSID will be one
SW2 #
Note
The default
LECID
-1, indicates that the LECS is not used on this switch. The
default value (-1) is used as the
LECID
on switches participating in LNNI that are
running only the LES/BUS (see next section, “Configuring LNNI Distributed
LES/BUS servers
”).
4.
On both SW1 and SW2 enter the
set lnnistatus
command to enable LNNI and SCSP (Server
Cache Synchronization Protocol).
SW1 # set lnnistatus
LNNIStatus(Disabled) : enable
SCSPStatus(Disabled) : enable
SW1 #
Enter the
show lnnistatus
command to make certain that LNNI has started on each switch
SW1 # show lnnistatus
LNNI Status : Enabled
SCSP Status : Enabled
SW1 #
5.
On both SW1 and SW2, use the
start les
and
start lecs
commands to start LANE services
SW1 # start les
NOTICE - 'ZLESSRV' ***** LES started *****
SW1 # start lecs
NOTICE - 'LECS' ***** LECS started *****
SW1 #