2-20 SmartSwitch ATM User Guide

Creating an Emulated LAN

IP Over ATM and LANE

1.

On both SW1 and SW2, enter the

stop lecs

command to make sure each LECS is down

SW1 # stop lecs

Confirm(y/n)?:y

NOTICE - 'LECS' ***** LECS shutdown *****

SW1 #

2.

On both SW1 and SW2, enter the

stop les

command to stop each switch’s LES and BUS

SW1 # stop les

STOPPING LES/BUS

Confirm(y/n)?:y

NOTICE - 'ZLESSRV' ***** LES shutdown *****

SW1 #

3.

On both SW1 and SW2, enter the

set lnniinfo

command to assign a number to each switch’s

LECS. Make sure that each

LECSID

is unique.

SW1 # set lnniinfo

LECSID(-1) : 0

— On SW1, LECSID will be zero

SW1 #

Similarly, on SW2, enter the

set lnniinfo

command, specifying a different LECSID for SW2

SW2# set lnniinfo

LECSID(-1) : 1

— On SW2, LECSID will be one

SW2 #

Note

The default

LECID

-1, indicates that the LECS is not used on this switch. The

default value (-1) is used as the

LECID

on switches participating in LNNI that are

running only the LES/BUS (see next section, “Configuring LNNI Distributed
LES/BUS servers

”).

4.

On both SW1 and SW2 enter the

set lnnistatus

command to enable LNNI and SCSP (Server

Cache Synchronization Protocol).

SW1 # set lnnistatus

LNNIStatus(Disabled) : enable

SCSPStatus(Disabled) : enable

SW1 #

Enter the

show lnnistatus

command to make certain that LNNI has started on each switch

SW1 # show lnnistatus

LNNI Status : Enabled

SCSP Status : Enabled

SW1 #

5.

On both SW1 and SW2, use the

start les

and

start lecs

commands to start LANE services

SW1 # start les

NOTICE - 'ZLESSRV' ***** LES started *****

SW1 # start lecs

NOTICE - 'LECS' ***** LECS started *****

SW1 #