beautypg.com

Cabletron Systems Smart 04-0053-01 User Manual

Page 43

background image

SmartSwitch ATM User Guide 2-25

IP Over ATM and LANE

Creating an Emulated LAN

To see a list of servers (LES/BUS or SMS servers) known to a particular LNNI LECS, enter the

show lecsserverlist

command on a switch running an LNNI LECS:

SW1 # show lecsserverlist

ELANNumber(ALL) : 1

LES/SMS servers known for ELAN 1

==============================================================================

ATM Address : 39:00:00:00:00:00:00:00:00:00:A3:87:0B:00:00:1D:A3:87:0B:03

Learned From (LECS): 39:00:00:00:00:00:00:00:00:00:A3:87:0B:00:00:1D:A3:87:0B:01

Type : LES

Alive Time (secs) : 28

Locally Attached : Yes

Config Direct VCC : 0/47

Server ID : 0x0000

LECID Range : 0x0001 - 0x03FF

ATM Address : 39:00:00:00:00:00:00:00:00:00:BD:AE:20:00:00:1D:BD:AE:20:03

Learned From (LECS): 39:00:00:00:00:00:00:00:00:00:A3:87:0B:00:00:1D:A3:87:0B:01

Type : LES

Alive Time (secs) : 27

Locally Attached : Yes

Config Direct VCC : 0/59

Server ID : 0x0001

LECID Range : 0x0400 - 0x07FF

ATM Address : 39:00:00:00:00:00:00:00:00:00:BF:BA:26:00:00:1D:BF:BA:26:03

Learned From (LECS): 39:00:00:00:00:00:00:00:00:00:BF:BA:26:00:00:1D:BF:BA:26:01

Type : LES

Alive Time (secs) : 21

Locally Attached : No

— LES/BUS of this switch (SW3) is not associated with switch SW1

Config Direct VCC : --

Server ID : --

LECID Range : --

SW1 #

In this example,

show lecsserverlist

is entered on SW1. Notice that the parameter

Locally Attached

indicates

whether the server is associated with the LECS on the switch on which the

show lecsserverlist

command was

executed. If the server is associated with this switch’s LECS (SW1),

Locally Attached

returns

yes

. If the server is

associated with an LECS on a different switch,

Locally Attached

returns

no

.