Cabletron Systems Smart 04-0053-01 User Manual
Page 43

SmartSwitch ATM User Guide 2-25
IP Over ATM and LANE
Creating an Emulated LAN
To see a list of servers (LES/BUS or SMS servers) known to a particular LNNI LECS, enter the
show lecsserverlist
command on a switch running an LNNI LECS:
SW1 # show lecsserverlist
ELANNumber(ALL) : 1
LES/SMS servers known for ELAN 1
==============================================================================
ATM Address : 39:00:00:00:00:00:00:00:00:00:A3:87:0B:00:00:1D:A3:87:0B:03
Learned From (LECS): 39:00:00:00:00:00:00:00:00:00:A3:87:0B:00:00:1D:A3:87:0B:01
Type : LES
Alive Time (secs) : 28
Locally Attached : Yes
Config Direct VCC : 0/47
Server ID : 0x0000
LECID Range : 0x0001 - 0x03FF
ATM Address : 39:00:00:00:00:00:00:00:00:00:BD:AE:20:00:00:1D:BD:AE:20:03
Learned From (LECS): 39:00:00:00:00:00:00:00:00:00:A3:87:0B:00:00:1D:A3:87:0B:01
Type : LES
Alive Time (secs) : 27
Locally Attached : Yes
Config Direct VCC : 0/59
Server ID : 0x0001
LECID Range : 0x0400 - 0x07FF
ATM Address : 39:00:00:00:00:00:00:00:00:00:BF:BA:26:00:00:1D:BF:BA:26:03
Learned From (LECS): 39:00:00:00:00:00:00:00:00:00:BF:BA:26:00:00:1D:BF:BA:26:01
Type : LES
Alive Time (secs) : 21
Locally Attached : No
— LES/BUS of this switch (SW3) is not associated with switch SW1
Config Direct VCC : --
Server ID : --
LECID Range : --
SW1 #
In this example,
show lecsserverlist
is entered on SW1. Notice that the parameter
Locally Attached
indicates
whether the server is associated with the LECS on the switch on which the
show lecsserverlist
command was
executed. If the server is associated with this switch’s LECS (SW1),
Locally Attached
returns
yes
. If the server is
associated with an LECS on a different switch,
Locally Attached
returns
no
.